Abstract

ABSTRACT
Introduction: When treating edentulisum, severely resorbed mandibular ridges are a prevalent issue. Attachments could be used to enhance retention. For removable distal extension prosthesis, extra coronal attachments enhance retention. During mastication and removal, micro and macro movement between the retentive surfaces of an attachment causes wear and reduces the retentive capacity over time. Using CAD/CAM technology, more accurate frameworks with improved retention should be expected.
Objective: was to compare the retention of conventional and CAD/CAM fabricated extra coronal attachments for a removable partial denture.
Methodology: - Retention of four extra coronal attachments of different materials and methods of fabrication was evaluated. The attachments were divided into two different groups according to the material used and whether the attachment was fabricated using the conventional method or CAD/CAM technology. Using a Universal testing machine, the difference in retention was compared between the groups.
Results: Data was collected, tabulated, and statistically analyzed using the appropriate test. In group I the mean force needed to dislodge the female clip before and after cyclic loading was 46.69N and 32.13N respectively and in group II the mean force needed was 59.07N and 42.44N respectively.
Conclusion: In comparison to conventional extra-coronal attachment, CAD/CAM fabricated extra-coronal attachment had a highly significant retentive force.

DOI

10.21608/adjalexu.2022.139618.1280

Keywords

retention, Extra coronal attachments, CAD/CAM, Removable Partial Denture

Authors

First Name

Hala

Last Name

Selim

MiddleName

-

Affiliation

Prosthodontics Department, Faculty of Dentistry, Alexandria University, Egypt

Email

halaselim5@outlook.com

City

-

Orcid

-

First Name

Ahmed

Last Name

Abdel Hakim

MiddleName

Adel

Affiliation

Removable Prosthodontics, Faculty of dentistry , Alexandria University , Egypt

Email

ahmedaahakim@yahoo.com

City

-

Orcid

-

First Name

Lucette

Last Name

Segaan

MiddleName

-

Affiliation

Professor, Department of Prosthodontics, Faculty of dentistry, Alexandria university, Alexandria, Egypt.

Email

lucettesegaan@gmail.com

City

-

Orcid

-

Volume

48

Article Issue

2

Related Issue

42600

Issue Date

2023-08-01

Receive Date

2022-05-24

Publish Date

2023-08-01

Page Start

173

Page End

178

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_309625.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=309625

Order

27

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

EVALUATION OF THE RETENTION OF CONVENTIONAL VERSUS CAD/CAM FABRICATED EXTRA CORONAL ATTACHMENTS FOR REMOVABLE PARTIAL DENTURE (IN-VITRO STUDY)

Details

Type

Article

Created At

30 Dec 2024