Abstract

Background: Limited data is present upon the accuracy of algorithms present inside CAD/CAM software regarding its effect on reverse taper blocking and furthermore on its effect on the internal fit.
Aim: To evaluate the effect of two blocking methods of reverse taper preparation (conventional wax blocking and digital software's algorithm) on the internal fit of CAD/CAM monolithic zirconia crowns and to compare the internal fit between zirconia crowns constructed over blocked preparation and 12º Total Occlusal Convergence (TOC).
Material and methods: Thirty CAD/CAM monolithic zirconia crowns were constructed over 3D printed dies. They were divided into three groups, each (n=10) according to the degree of TOC ;12 º, -4 º and -8 º reverse taper. Group II and group III will be further subdivided into 2 sub-groups (n=5) according to the method of reverse taper blocking; A, conventional wax blocking technique and B, digital method. 3D models were created to simulate a reduced upper molar. All dies were scanned to create STL files. Internal fit was assessed with the silicone replica technique. Kruskal-Wallis test was used to compare between the groups. Dunn's test was used for pair-wise comparisons when Kruskal-Wallis or Friedman's test is significant.
Results: There were no statistically significant difference between internal gap distance measurements of the five groups and between methods.
Conclusion: Under the conditions of this study, the internal fit of the zirconia crowns constructed over reverse tapered preparations were within the clinically accepted values (300µ) except for -8o digitally blocked specimen (315.6µ).

DOI

10.21608/jfcr.2024.243405.1060

Keywords

3D printed dies, internal fit, reverse taper, undercut, Zirconia

Authors

First Name

Fady

Last Name

Nageeb

MiddleName

Remo

Affiliation

19 Ebn El St 8

Email

drfadyr77@gmail.com

City

Cairo

Orcid

0009-0004-8142-2498

Volume

4

Article Issue

1

Related Issue

48059

Issue Date

2024-06-01

Receive Date

2023-10-18

Publish Date

2024-06-01

Page Start

42

Page End

57

Online ISSN

2786-023X

Link

https://jfcr.journals.ekb.eg/article_357516.html

Detail API

https://jfcr.journals.ekb.eg/service?article_code=357516

Order

8

Type

Original research articles

Type Code

1,936

Publication Type

Journal

Publication Title

Journal of Fundamental and Clinical Research

Publication Link

https://jfcr.journals.ekb.eg/

MainTitle

Effect of two Blocking Reverse Taper Preparation Methods on the Internal Fit of CAD/CAM Monolithic Zirconia Crowns (An In-vitro study)

Details

Type

Article

Created At

28 Dec 2024