Beta
357515

Comparing Accuracy Of Surgical Guides Fabricated By Additive Method (3D Printing) Versus Subtractive Method (Milling by CAD/CAM) for Prosthetically Driven Implant Placement “An I

Article

Last updated: 28 Dec 2024

Subjects

-

Tags

Pharmaceutical, Dental, and medical disciplines whether they are descriptive, analytical, experimental, or basic studies

Abstract

Background: The accuracy of prosthetically driven implant placement relies heavily on the technique used for surgical guide fabrication. However, a significant challenge arises in accurately transferring the planned implant position to the surgical site. Aim of the study: the aim of this in vitro study is to compare between the accuracy of additive (3D printing) and subtractive methods (CAD/CAM Milling) in surgical guides fabrication. Materials and methods: cone beam computed tomography (CBCT) obtained from dental implant software library of demo case with missing mandibular first molar was used. The mandible was 3D printed to obtain the master cast. Prosthetically driven implant planning was done and fabrication of surgical guides using additive (3D Printing) and subtractive (CAD/CAM Milling) methods. Twenty-four duplicates of master cast were obtained by epoxy resin models. Models were divided into two equal groups according to the fabrication method. Implants were placed following guided surgery protocol using tooth supported surgical guides, followed by digitally scanning using scanning bodies connected to the implants. Supper imposition of planned and placed implants was performed using Geomagic software, and degree of deviation was calculated at point of entry, apical point, and angular deviation. The Mann-Whitney U test was used for comparison (P ≤0.05). Results: Statistically significant difference between SLA and milled groups was found for angular deviation (P

DOI

10.21608/jfcr.2024.253520.1064

Keywords

surgical guides, 3D printing, milling, prosthetically driven implant placement, stereolithography

Authors

First Name

Mounir

Last Name

Stino

MiddleName

Shafik

Affiliation

Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Misr International University, Cairo, Egypt

Email

mounir090436@miuegypt.edu.eg

City

Cairo

Orcid

0009-0000-5611-526X

First Name

Tarek

Last Name

Morsy

MiddleName

Salah

Affiliation

Crown and Bridge, Faculty of Dentistry, Misr International University, Cairo, Egypt

Email

drtareksalah69@gmail.com

City

Cairo

Orcid

0000-0001-6724-9458

First Name

Talaat

Last Name

Samhaan

MiddleName

Mohamed

Affiliation

Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Misr International University, Cairo, Egypt

Email

talaat.samhan@miuegypt.edu.eg

City

cairo

Orcid

0000-0002-3233-5062

Volume

4

Article Issue

1

Related Issue

48059

Issue Date

2024-06-01

Receive Date

2023-12-20

Publish Date

2024-06-01

Page Start

30

Page End

41

Online ISSN

2786-023X

Link

https://jfcr.journals.ekb.eg/article_357515.html

Detail API

https://jfcr.journals.ekb.eg/service?article_code=357515

Order

8

Type

Original research articles

Type Code

1,936

Publication Type

Journal

Publication Title

Journal of Fundamental and Clinical Research

Publication Link

https://jfcr.journals.ekb.eg/

MainTitle

Comparing Accuracy Of Surgical Guides Fabricated By Additive Method (3D Printing) Versus Subtractive Method (Milling by CAD/CAM) for Prosthetically Driven Implant Placement “An In-Vitro Study”

Details

Type

Article

Created At

28 Dec 2024