301017

Accuracy Assessment Of Bracket Placement By Indirect Bonding Technique Using Three-Dimensional Imaging And Steroelithographic Printing Technique

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

-

Abstract

Objective: this clinical trial was designed to assess the accuracy of bracket placement by indirect bonding by using three dimensional imaging and steroelithographic printing technique.
Materials and methods: a clinical trial was held on ten patients were planned to be bonded by full digital indirect bonding tray for upper arch. Intra- oral scanning of each patient was held after indirect bonding to get STL file for evaluation. Vertical brackets positions of total 120 brackets bonded were measured and evaluated. Intra class correlation and Bland Altman plot test were used to assess the accuracy of vertical bracket position of the full digital transfer tray.

Results: considering the whole units (120 units), excellent reliability and internal consistency (ICC>0.9) with p value < 0.001* with High level of agreement P value =0.089. For lateral incisors, canines and premolar groups, there was good reliability (0.9> ICC>0.75) with high level of agreement with p value = 0.068, 0.706 and 0.794 in order. An acceptable reliability (0.75>ICC>0.5) was found in central incisors and molars groups. The central incisors and molars groups exhibited a proportional bias in agreement test with by P value 0.047 *, 0.019* in order which is clinically insignificant. There was no statistical difference between the mean differences of the five groups P value = 0.185 .with range of mean differences (0.002:0.175) mm which was not clinical significant.
Conclusion: this protocol transferred the planed vertical brackets position from the virtual setup to the patient was generally highly accurate and reliable technique.

DOI

10.21608/eos.2023.202537.1067

Keywords

Indirect bonding, steroelithography, 3D printing, digital transfer tray

Authors

First Name

Ahmed

Last Name

El Rashidy

MiddleName

Magdy

Affiliation

Department of Orthodontics, faculty of Dentistry, Minia University,Minia, Egypt

Email

doctorahmed944@gmail.com

City

-

Orcid

-

First Name

wael

Last Name

Refai

MiddleName

mohamed

Affiliation

Head of department of Orthodontics , faculty of dentistry, minia university, Minia, Egypt

Email

w_refai_67@hotmail.com

City

cairo

Orcid

-

Volume

63

Article Issue

1

Related Issue

41534

Issue Date

2023-06-01

Receive Date

2023-03-29

Publish Date

2023-06-01

Page Start

130

Page End

148

Print ISSN

1110-435X

Online ISSN

2812-5258

Link

https://eos.journals.ekb.eg/article_301017.html

Detail API

https://eos.journals.ekb.eg/service?article_code=301017

Order

11

Type

Original Article

Type Code

1,120

Publication Type

Journal

Publication Title

Egyptian Orthodontic Journal

Publication Link

https://eos.journals.ekb.eg/

MainTitle

Accuracy Assessment Of Bracket Placement By Indirect Bonding Technique Using Three-Dimensional Imaging And Steroelithographic Printing Technique

Details

Type

Article

Created At

25 Dec 2024