Abstract

This study aims to obtain a clean environment through agricultural activities by developing and evaluating the performance of a cyclone separating unit attached to threshers. Threshing in traditional method depends on emitting chopped wheat straw (Tibn) off the threshers freely in the air and then collected manually by operators causing air pollution and affecting operators' health. The developed cyclone in this study separates dust from the airstream and simultaneously collect the chopped wheat straw instead of operators. According to the obtained data from theoretical calculations (Table 1), the modifications on 2D2D cyclone. The tested performance parameters of the developed cyclone are: four airstream velocities (ASV) of 2.3, 3.6, 4.7 and 5.5 m/s; cyclone inlet dimensions (CID) of (A) 20x30; (B) 25x35; (C) 35x45 cm for width and height, respectively; vortex finder length (VFL) of 50, 60 and 70 cm; cyclone outlets ratios (COR) chopped wheat straw and airstream outlet diameters of 15, 20, 25 and 20, 25, 30 cm for chopped wheat straw and airstream outlet represents ratios of 0.75, 0.80 and 0.83, respectively. The results were summarized in the following points: Separation and collection efficiency value by developed cyclone was 99.8% at inlet velocity of 4.7m/s, vortex finder length of 50 cm, with inlet dimensions of 25x35 cm under cyclone outlet ratio of 0.8. The maximum values of the rising dust was 6.8 mg/m3under the same mentioned conditions while increased by97.5 % with traditional method (without cyclone). Total costs for packing chopped wheat straw under mentioned conditions decreased by 80% in case of using the developed cyclone comparing to the traditional method. It is recommended to manufacture the developed cyclone with vortex finder length of 50 cm, with inlet dimensions of 25x35 cm at outlet ratio of 0.8 to lessen the environmental pollution and conserve laborers' health.
 

DOI

10.21608/ejar.2019.111105

Keywords

environment, Cyclone, Pressure drop, tangential outlet, collection efficiency

Authors

First Name

M.

Last Name

EL-TANTAWY

MiddleName

M.

Affiliation

Agricultural Engineering Research Institute (AEnRI), ARC, Giza, Egypt

Email

-

City

-

Orcid

-

First Name

Y.

Last Name

RAMADAN

MiddleName

Y.

Affiliation

Agricultural Engineering Research Institute (AEnRI), ARC, Giza, Egypt

Email

-

City

-

Orcid

-

First Name

ATALLAH

Last Name

MERVAT

MiddleName

M.

Affiliation

Agricultural Engineering Research Institute (AEnRI), ARC, Giza, Egypt

Email

-

City

-

Orcid

-

First Name

Y.

Last Name

SHAROBEEM

MiddleName

F.

Affiliation

Agricultural Engineering Research Institute (AEnRI), ARC, Giza, Egypt

Email

-

City

-

Orcid

-

Volume

97

Article Issue

4

Related Issue

16881

Issue Date

2019-12-01

Receive Date

2018-11-28

Publish Date

2019-12-01

Page Start

747

Page End

768

Print ISSN

1110-6336

Online ISSN

2812-4936

Link

https://ejar.journals.ekb.eg/article_111105.html

Detail API

https://ejar.journals.ekb.eg/service?article_code=111105

Order

16

Type

Original Article

Type Code

1,041

Publication Type

Journal

Publication Title

Egyptian Journal of Agricultural Research

Publication Link

https://ejar.journals.ekb.eg/

MainTitle

DEVELOPMENT OF A CYCLONE SEPARATING UNIT ATTACHING TO LOCALTHRESHERS FOR CLEAN ENVIRONMENT

Details

Type

Article

Created At

22 Jan 2023