In high voltage substation it's important to fast simulate and analysis any fault or disturbed in the substation, SCADA system allow to faster analysis of real time and high resolution for the data which allows the operator to take faster decisions at any fault or abnormal condition in the substation. This paper will discuss Supervisory Control and Data Acquisition (SCADA), where the accuracy meaning is a control system with applications in managing large-scale for
industrial operations. The remote substation consists of protection and high voltage equipment that are directly interfaced to supervision center national control; fiber optical connection consists of high quality and fast transmitter data from the protection equipment by SCADA system, power system supervision and power Systems control all working in a coordinated automatic fashion. Data acquisition refers to collecting data in the form of measured analog current or voltages values or the Open or closed status of contact points. Power system supervision is carried out by Operators and maintenance engineers through this acquired data either at a remote site represented by computer displays and graphically wall displays or locally, at the Device site, in the form of frontpanel displays and laptop computers.

DOI

10.21608/iceeng.2016.30305

Keywords

high voltage, Protection relay, SCADA and Fiber Optical

Authors

First Name

Amer

Last Name

Elghaffar

MiddleName

Nasr A.

Affiliation

Researchers, Electrical Engineering Department, Minia University, Cairo University.

Email

-

City

-

Orcid

-

First Name

Karim

Last Name

Ibrahim

MiddleName

M.

Affiliation

Researchers, Electrical Engineering Department, Minia University, Cairo University.

Email

-

City

-

Orcid

-

First Name

Yehia

Last Name

Ali

MiddleName

Sayed M.

Affiliation

Professor Electrical Engineering Department, Minia University, Minia, Egypt.

Email

-

City

-

Orcid

-

First Name

Adel

Last Name

Mohamed

MiddleName

A.Elbaset

Affiliation

Professor Electrical Engineering Department, Minia University, Minia, Egypt.

Email

-

City

-

Orcid

-

Volume

10

Article Issue

10th International Conference on Electrical Engineering ICEENG 2016

Related Issue

5244

Issue Date

2016-04-01

Receive Date

2019-04-17

Publish Date

2016-04-01

Page Start

1

Page End

19

Print ISSN

2636-4433

Online ISSN

2636-4441

Link

https://iceeng.journals.ekb.eg/article_30305.html

Detail API

https://iceeng.journals.ekb.eg/service?article_code=30305

Order

24

Type

Original Article

Type Code

833

Publication Type

Journal

Publication Title

The International Conference on Electrical Engineering

Publication Link

https://iceeng.journals.ekb.eg/

MainTitle

Smart Transmit abnormal Condition in High Voltage Substation by SCADA System between Protection Equipment’s and National Control Center

Details

Type

Article

Created At

22 Jan 2023