Abstract:
Purpose: to evaluate the effect of repeated heat pressing and thermocycling on micro-shear bond strength of PEEK to resin cement.
Methods: A total of 30 PEEK specimens 10 mm x 10 mm x 2 mm were prepared and divided to three groups (n=10). Group I was pressed using new PEEK, Group II ; 50% new PEEK and 50% reprocessed PEEK, and Group III ; 100% reprocessed PEEK. Bonding surfaces were sandblasted and thin layer of bonding agent was applied and polymerized. Plastic tygon tubes with an inner diameter of 1 mm and a height of 1.5 mm were fixed on the sample and filled with dual polymerized self etch self adhesive resin cement and cured. Half the specimens in each group (n=5) underwent 5000 thermocycles (5‐55°C) before shear bond strength (µSBS) test. Two-way Analysis of Variance (ANOVA) studied the effect of PEEK condition, thermocycling and their interaction on mean micro-shear bond strength µSBS. Bonferroni's post-hoc test was used for pair-wise comparisons when ANOVA test is significant.
Results: The PEEK condition (regardless of thermocycling) had a statistically significant effect on mean µSBS (P-value = 0.001, Effect size = 0.455). Thermocycling (regardless of PEEK condition) also had a statistically significant effect on mean µSBS (P-value = 0.002, Effect size = 0.331). The interaction between two variables had no statistically significant effect on mean µSBS (P-value = 0.442, Effect size = 0.066).
Conclusion: Both repeated heat pressing and thermocycling had a negative effect on micro-shear bond strength of resin cement to PEEK

DOI

10.21608/edj.2021.90733.1752

Keywords

PEEK, heat pressing, reprocessing, thermocycling, Shear bond strength

Authors

First Name

Ahmed

Last Name

Arafa

MiddleName

-

Affiliation

Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Email

ahm.arafa@dent.bsu.edu.eg

City

-

Orcid

0000-0002-5128-3253

First Name

Marwa

Last Name

Emam

MiddleName

-

Affiliation

Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt

Email

marwaemam@asfd.asu.edu.eg

City

-

Orcid

0000-0003-0856-0689

Volume

67

Article Issue

4

Related Issue

28415

Issue Date

2021-10-01

Receive Date

2021-08-18

Publish Date

2021-10-01

Page Start

3,617

Page End

3,627

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_201897.html

Detail API

https://edj.journals.ekb.eg/service?article_code=201897

Order

32

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Effect Of Repeated Heat Pressing And Thermocycling On Micro Shear Bond Strength Of Polyetheretherketone (PEEK) To Resin Cement

Details

Type

Article

Created At

22 Jan 2023