Purpose: This study aimed to evaluate the accuracy of fit between implant and abutment using different types of abutments.
Methods: A total of 32 titanium implants with 3.5mm diameter, 12mm length and conical connection were used in this study. All implants were randomly divided into four equal groups according to the type of the abutment used as follows: Group I (Control Group): Ready-made Titanium abutment . Group II: Custom-made Gold abutment . Group III: Custom-made Co-Cr abutment with prefabricated machined Co-Cr base . Group IV: Custom-made Fully Casted Co-Cr abutment. Abutments for groups II, III, IV were fabricated using the conventional casting technique to obtain custom-made gold abutments for group II and custom-made Co-Cr abutments for groups III, IV. All the abutments were tightened at 35 N/cm using manual Torque Wrench. The x-ray sensor was placed parallel to the implant and a radiograph was taken for each sample. The distance from the end of the base of the abutment till the beginning of the screw holes of the implant was measured in mm. Data were statistically studied.
Results: Results showed that Group IV had the statistically significantly highest mean value. Group III showed statistically significantly lower mean value. There was no statistically significant difference between Group I and Group II; both showed statistically significantly lowest mean values.
Conclusions: Within the limitations of this study, it was concluded that: Custom-made Co-Cr abutments with prefabricated Co-Cr base revealed promising results. Casted connections don't seem to be a good alternative to machined connections.

DOI

10.21608/edj.2020.37695.1196

Keywords

Ready-made titanium abutment, custom-made gold abutment, Custom-made Co-Cr abutment, conical connection, abutment fit

Authors

First Name

Shereen

Last Name

Elsayed

MiddleName

-

Affiliation

Fixed Prosthodontics Department, Faculty of Dentistry, Cairo University, Cairo, Egypt. Oral and Maxillofacial Department, Faculty of Dentistry, Umm Alqura University, Makkah, KSA.

Email

shereenabdelmeguid@gmail.com

City

Cairo

Orcid

-

First Name

Alaa

Last Name

Makke

MiddleName

-

Affiliation

Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Umm Alqura University, Makkah, KSA

Email

alaamakke@hotmail.com

City

-

Orcid

-

First Name

Khaled

Last Name

Elbanna

MiddleName

-

Affiliation

Oral and Maxillofacial Surgery, Faculty of Dentistry, Umm Alqura University, Makkah KSA

Email

khalidbanna@yahoo.com

City

-

Orcid

-

Volume

66

Article Issue

Issue 4 - October (Fixed Prosthodontics, Removable Prosthodontics and Dental Materials)

Related Issue

18081

Issue Date

2020-10-01

Receive Date

2020-08-05

Publish Date

2020-10-01

Page Start

2,529

Page End

2,539

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_120851.html

Detail API

https://edj.journals.ekb.eg/service?article_code=120851

Order

11

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

-

Details

Type

Article

Created At

22 Jan 2023