Beta
78541

Biomechanical evaluation of double Y-shaped versus conventional straight titanium miniplates for the treatment of mandibular angle fractures

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Aim of this experimental study: Was to test the resistance to mechanical force of a double
Y- shaped titanium miniplate versus conventional straight titanium miniplate for the treatment of
mandibular angle fracture.
Materials and methods: Ten fresh sheep hemi mandibles, sectioned at the angle region, were
used to evaluate two plating techniques. One group (Group A) received fixation via a double Yshaped
titanium miniplate and the second group (group B) via a six-hole conventional straight
non-compression titanium miniplate .Each hemi mandible in group A and group B was subjected to
tensile forces using universal testing machine.
Results: During the test, the group (A) fixed by double Y-shaped miniplate, the plates were
fractured in all group samples at mean of the Yield load (745N). The mean degree of displacement
of this group was 7.8mm). While in group (B), the conventional straight titanium mini plates were
fractured at force (the mean; 665.6N). The mean of degree of displacement of this group was
7.8mm)
Conclusion; Double Y-shaped miniplate with 6 holes and 9.0 mm spacing had greater resistance
to displacement and provided more favorable biomechanical behavior than the conventional straight
miniplates in the repair of mandibular angle fractures.
 

DOI

10.21608/edj.2018.78541

Keywords

double Y shaped plate, angular fractures, conventional straight mini plate

Authors

First Name

Atef

Last Name

Hasanein

MiddleName

M

Affiliation

Lecturer, Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Al-Azhar University Cairo, (Boys) Egypt

Email

-

City

-

Orcid

-

First Name

Abdelmageed

Last Name

Alfakhrany

MiddleName

-

Affiliation

Lecturer, Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Al-Azhar University Cairo, (Boys) Egypt

Email

-

City

-

Orcid

-

Volume

64

Article Issue

Issue 4 - October (Oral Surgery)

Related Issue

11456

Issue Date

2018-10-01

Receive Date

2020-03-22

Publish Date

2018-10-01

Page Start

3,231

Page End

3,235

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_78541.html

Detail API

https://edj.journals.ekb.eg/service?article_code=78541

Order

14

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Biomechanical evaluation of double Y-shaped versus conventional straight titanium miniplates for the treatment of mandibular angle fractures

Details

Type

Article

Created At

22 Jan 2023