Purpose: To evaluate in-vivo the effect of CAD/CAM constructed dentures on the masticatory muscles activity using electromyography in comparison to conventionally constructed dentures.
Materials and Methods: Fourteen completely edentulous patients were randomly allocated to two equal groups. Patients in the first group received conventionally constructed complete dentures and patients in the second group received complete dentures constructed using CAD/CAM technology. After 30 days of denture use the anterior temporalis and superficial masseter muscles activity were measured by EMG. A cross over was performed for patients with conventional denture to CAD/CAM and vice versa and the dentures were used for further 30 days, after which measurements of anterior temporalis and superficial masseter muscles activity were taken using EMG. Electromyographic data was recorded and analyzed, mean values were compared by independent t-test to compare between the two groups as regard to muscle activity.
Results: There was a significant difference in the activity of the masseter muscles and the anterior temporalis muscles for the patients received CAD/CAM denture in comparison to those received the conventional denture, after 30 days of denture use (p < 0.05).
Conclusion: CAD/CAM constructed complete dentures produced higher muscle activity if compared to conventionally constructed complete dentures.

DOI

10.21608/edj.2019.76031

Authors

First Name

Mahmoud

Last Name

Mohamed

MiddleName

Darwish

Affiliation

Lecturer of Removable Prosthodontics, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt

Email

-

City

-

Orcid

-

First Name

Nasser

Last Name

Shaheen

MiddleName

Hussein

Affiliation

Associate Professor, Department of Removable Prosthodontics, College of Oral and Dental Surgery, Misr University for Science and Technology, Egypt

Email

nasser_shaheen@hotmail.com

City

-

Orcid

-

Volume

65

Article Issue

Issue 4 - October (Fixed Prosthodontics, Dental Materials, Conservative Dentistry & Endodontics)

Related Issue

10707

Issue Date

2019-10-01

Receive Date

2020-03-06

Publish Date

2019-10-01

Page Start

3,829

Page End

3,836

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_76031.html

Detail API

https://edj.journals.ekb.eg/service?article_code=76031

Order

29

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Comparative evaluation of the masticatory muscleS activity with CAD/CAM versus conventional complete denture using electromyography

Details

Type

Article

Created At

22 Jan 2023