Beta
40975

Assessment of glycemic control in patients with type 1 diabetes by using insulin pump integrated with real-time continuous glucose monitoring system

Thesis

Last updated: 06 Feb 2023

Subjects

-

Tags

Pediatrics

Advisors

Salah-El-Din, Nermin, Anwar, Ghada, Badawi, Noura

Authors

Ahmad, Muhammad Ahmad

Accessioned

2017-07-12 06:39:59

Available

2017-07-12 06:39:59

type

M.Sc. Thesis

Abstract

Objectives:Assess the safety and clinical effectiveness for initiating insulin pump integrated with RT-CGM compared to MDI therapy.Methods: The study included 10 patients with T1DM who were treated with MDI, their glycemic control was evaluated by CGMS and then shifted to CSII integrated with RT-CGM and their glycemic control was re-evaluated.Results:Significant improvement in glycemic control was achieved by insulin pump as compared to MDI, also a lot of missed data appeared by the use of CGMS compared to SMBG.Conclusion:CGMS and CSII in the terms of glycemic control are superior to SMBG and MDI regimens and are emerging as interesting devises in the management of diabetes.

Issued

1 Jan 2010

DOI

http://dx.doi.org/10.21473/iknito-space/34912

Details

Type

Thesis

Created At

28 Jan 2023