425142

Evaluation of the Donor Site Morbidity Following Harvesting of Thoracodorsal Artery Perforator Flap

Article

Last updated: 04 May 2025

Subjects

-

Tags

Flaps

Abstract

Background: The use of the thoracodorsal artery perforator
(TAP) flap preserves the latissimus dorsi (LD) muscle and,
Hence, reduces donor site morbidity and complications.
Objective: In this study, we evaluate the donor site morbidity
of the TAP flap regarding aesthetic and functional aspects.
Methods: In this study, we evaluated the resulting aesthetic
and functional consequences of the harvest of the thoracodorsal
artery perforator flap. This included postoperative donor
site complications. The shoulder function was evaluated 3-6
months post-operatively by the QUICKDASH scale. The donor
site scar quality and related problems were assessed six months
post-operatively by using three scar scoring systems (the patient
scar assessment scale, observer scar assessment scale, and
the Vancouver Scar Scale).
Results: Minimal donor site complications were reported
With three cases of wound dehiscenc,e two of them managed
Conservatively, one case of wound infection and one case of
seroma. We used three scar assessment scores, which showed
Good scar quality except for the cases where skin graft was used
to cover the donor site when its width exceeded 10cm. Regarding
functional outcome, we found normal shoulder movements
Except for the early limitation of abduction and forward elevation
that were improved with time.
Conclusion: The use TAP flap reduces donor site complications
and morbidity, and should be used when feasible as an
Alternative to the LD musculocutaneous flap.

DOI

10.21608/ejprs.2025.425142

Keywords

Thoracodorsal, Perforator, Flap, donor

Authors

First Name

MOHAMED

Last Name

SADAKA

MiddleName

SAAD

Affiliation

The Department of Plastic and Reconstructive Surgery, Faculty of Medicine, Tanta University

Email

-

City

Alexandria

Orcid

-

Volume

49

Article Issue

2

Related Issue

55420

Issue Date

2025-04-01

Receive Date

2025-04-30

Publish Date

2025-04-01

Page Start

115

Page End

121

Print ISSN

1110-0044

Online ISSN

2974-4709

Link

https://ejprs.journals.ekb.eg/article_425142.html

Detail API

http://journals.ekb.eg?_action=service&article_code=425142

Order

6

Type

Original Article

Type Code

1,110

Publication Type

Journal

Publication Title

The Egyptian Journal of Plastic and Reconstructive Surgery

Publication Link

https://ejprs.journals.ekb.eg/

MainTitle

Evaluation of the Donor Site Morbidity Following Harvesting of Thoracodorsal Artery Perforator Flap

Details

Type

Article

Created At

04 May 2025