Abstract

Purpose: This study aimed to evaluate the effect of anterior span length on the accuracy of the intraoral scanner.
Methodology: One model was used to represent two anterior bridge span lengths. One group had missing upper central incisors representing short-span length, and the other had missing upper central incisors and lateral incisors representing long-span. A laboratory scanner (inEos X5) obtained a scan to act as a reference. For each group, five scans were obtained by the intraoral scanner (CEREC Primescan). The data set from the intraoral scans was superimposed on the reference scan using reverse engineering software to determine the trueness. Regarding precision measurement, the five scans taken by the intraoral scanner were superimposed on each other. Comparison between short and long-span edentulous areas was performed using Wilcoxon signed rank.
Results: There was no statistically significant difference between the different span lengths, long span (0.12 ± 0.107 mm) was insignificantly higher than the short span (0.082 ±0.04 mm) as P=0.22. Regarding precision, the long span (0.07 ± 0.07 mm) was insignificantly lower than the short span (0.082 ±0.04 mm) as P=0.57.
Conclusion: The intraoral scanner showed high trueness and precision in both long and short spans.

DOI

10.21608/edj.2025.371310.3428

Keywords

span length, Trueness, Precision

Authors

First Name

Mariem

Last Name

Madboly

MiddleName

Sherif

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, Cairo University.

Email

mariam.sherif@dentistry.cu.edu.eg

City

-

Orcid

0009-0000-1941-8771

First Name

Omaima

Last Name

El mahallawy

MiddleName

-

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, Cairo University.

Email

oelmahallawi@dentistry.cu.edu.eg

City

Cairo

Orcid

0000-0002-0422-8315

First Name

Omnia

Last Name

Nabil

MiddleName

-

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, Cairo University. Division of Fixed Prosthodontics, School of Dentistry, Newgiza University

Email

omnianabil@dentistry.cu.edu.eg

City

-

Orcid

0000-0001-8067-2808

Volume

71

Article Issue

2

Related Issue

55192

Issue Date

2025-04-01

Receive Date

2025-03-25

Publish Date

2025-04-01

Page Start

1,637

Page End

1,645

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_423205.html

Detail API

http://journals.ekb.eg?_action=service&article_code=423205

Order

423,205

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

The Effect of Anterior Span Length on the Accuracy of Intraoral Scanner (an In-vitro study)

Details

Type

Article

Created At

04 May 2025