Abstract

Intraoral scanners (IOS) are reshaping modern dentistry by offering a digital alternative to traditional impression techniques. This review aims to analyze the accuracy, reproducibility, and patient satisfaction associated with IOS compared to conventional methods. A comprehensive review of academic. Studies were assessed for methodological strength, participant characteristics, and outcomes concerning accuracy, reproducibility, and patient satisfaction. Results suggest that IOS generally performs as well or better than traditional impression methods, especially in terms of precision and reproducibility, while also delivering high levels of patient satisfaction due to improved comfort. Challenges remain, such as the cost of the technology, the learning curve for practitioners, and some technical limitations. The findings suggest that standardizing methodologies and assessing long-term performance could aid in overcoming these barriers. This review also highlights the need for increased adoption through improved training and cost management.This review aims to provide a detailed evaluation of the accuracy, reproducibility, and patient satisfaction associated with intraoral scanners compared to traditional impression techniques in dentistry.

DOI

10.21608/edj.2024.340055.3279

Keywords

accuracy, Reproducibility, patient satisfaction, Intra oral scanners

Authors

First Name

Rafik

Last Name

Mina

MiddleName

K.G

Affiliation

Associate Professor, Egyptian Armed Forces Military Medical Academy

Email

rminadent@hotmail.com

City

Cairo

Orcid

0000-0001-9023-5433

Volume

71

Article Issue

2

Related Issue

55192

Issue Date

2025-04-01

Receive Date

2024-11-29

Publish Date

2025-04-01

Page Start

1,477

Page End

1,483

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_423190.html

Detail API

http://journals.ekb.eg?_action=service&article_code=423190

Order

423,190

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Accuracy, reproducibility and patient satisfaction of Intra oral scanners usage in comparison to conventional impressions, A review of literature.

Details

Type

Article

Created At

04 May 2025