393517

A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults: radiological and functional outcomes

Article

Last updated: 29 Mar 2025

Subjects

-

Tags

Orthopedic Surgery and Traumatology

Abstract

Abstract
Background: Management of Neck Of Femur fractures is associated with high rates of complications , The most common method of fixations are the Dynamic Hip Screw and Cannulated screws .
Aim and objectives: to evaluate and compare the result two surgical technique regarding the complications & the functional outcome .
Subjects and methods : Thirty patients with femoral neck fractures were enrolled in the study and divided into two groups. Cannulated screw treatment for group A and Dynamic Hip Screw treatment for group B. This prospective study was conducted at the orthopedic department of Aswan University Hospital. Functional outcomes is determined by the Harris Hip Score at the final follow-up
Results: The union time was significantly longer in the Cannulated Screw group (5.4 ± 1.33 months) than the Dynamic Hip Screw group (4.5 ± 0.52 months). no significant differences between the two groups regarding the nonunion , avascular necrosis , & the Harris Hip Score .
Conclusion: the Dynamic Hip Screw has the advantage of rapid union rate and more stable fixation
Keywords : Dynamic Hip Screw , Cannulated Screw , Neck of Femur .

DOI

10.21608/aumj.2024.329553.1151

Keywords

Keywords : Dynamic Hip Screw, canulated screw, Neck of Femur

Authors

First Name

Hesham

Last Name

Refae

MiddleName

-

Affiliation

Department of orthopedic surgery, Faculty of Medicine, Aswan University

Email

heshamhamed@med.aswu.edu.eg

City

-

Orcid

0000-0002-6923-1988

First Name

Ahmed

Last Name

Abdelwahab

MiddleName

Mohammed

Affiliation

Department of orthopedic surgery, Faculty of Medicine, Aswan University

Email

ahmedcamp753@gmail.com

City

luxor

Orcid

-

First Name

Mohamed

Last Name

salman

MiddleName

-

Affiliation

Department of orthopedic surgery, Faculty of Medicine, Aswan University

Email

muhammadsalman@med.aswu.edu

City

Cairo

Orcid

0009-0000-6567-0046

First Name

Ebeed

Last Name

Yasin

MiddleName

-

Affiliation

Department of orthopedic surgery, Faculty of Medicine, Aswan University

Email

drebeedyasin@med.aswu.edu.eg

City

Aswan

Orcid

0000000231923583

Volume

5

Article Issue

1

Related Issue

54545

Issue Date

2025-03-01

Receive Date

2024-10-19

Publish Date

2025-03-18

Page Start

23

Page End

31

Print ISSN

2735-3109

Online ISSN

2735-3117

Link

https://aumj.journals.ekb.eg/article_393517.html

Detail API

http://journals.ekb.eg?_action=service&article_code=393517

Order

3

Type

Original Article

Type Code

2,278

Publication Type

Journal

Publication Title

Aswan University Medical Journal

Publication Link

https://aumj.journals.ekb.eg/

MainTitle

A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults: radiological and functional outcomes

Details

Type

Article

Created At