393520

What is the difference in intraoperative complications between using cannulated screws and dynamic hip screws for fixation of femoral neck fracture?

Article

Last updated: 29 Mar 2025

Subjects

-

Tags

Orthopedic Surgery and Traumatology

Abstract

Abstract
Background: Operative treatment of a femoral neck fracture necessitates meticulous technique since intraoperative excessive image exposure and blood loss can significantly impact union and the overall outcome. objectives: The work aimed to evaluate and compare the intraoperative compactions between the cannulated screws and dynamic hip screws for fixation of the femoral neck fracture. Subjects and methods: Thirty patients with femoral neck fractures were enrolled in this prospective study and divided into two groups. Cannulated screw fixation for group A and dynamic hip screw fixation for group B. We compared the two groups regarding intraoperative complications: C-arm exposure, blood loss, and implant failure. Results: The intraoperative blood loss was (160 ± 47.06 ml) in the cannulated screws and (440 ± 188.22 ml) in the dynamic hip screw (p-value <0.001). The C-arm exposure time was significantly higher in the canned fixation group (30 ± 9.26 seconds) compared to the dynamic hip screw group (20.3 ± 11.41 seconds). Conclusion: the Cannulated fixation recorded more intraoperative image exposure but lesser operative time than Dynamic hip screws during fixation of the neck of femur fracture

DOI

10.21608/aumj.2024.329555.1152

Keywords

Keywords : Dynamic Hip Screw, Cannulated Screw, Neck of Femur

Authors

First Name

Hesham

Last Name

Refae

MiddleName

-

Affiliation

Department of orthopedic surgery, Faculty of Medicine, Aswan University

Email

heshamhamed@med.aswu.edu.eg

City

-

Orcid

0000-0002-6923-1988

First Name

Ahmed

Last Name

Abdelwahab

MiddleName

Mohammed

Affiliation

Department of orthopedic surgery, Faculty of Medicine, Aswan University

Email

ahmedcamp753@gmail.com

City

luxor

Orcid

-

First Name

Mohamed

Last Name

salman

MiddleName

-

Affiliation

Department of orthopedic surgery, Faculty of Medicine, Aswan University

Email

muhammadsalman@med.aswu.edu

City

Cairo

Orcid

0009-0000-6567-0046

First Name

Ebeed

Last Name

Yasin

MiddleName

-

Affiliation

Department of orthopedic surgery, Faculty of Medicine, Aswan University

Email

drebeedyasin@med.aswu.edu.eg

City

Aswan

Orcid

0000000231923583

Volume

5

Article Issue

1

Related Issue

54545

Issue Date

2025-03-01

Receive Date

2024-10-19

Publish Date

2025-03-18

Page Start

1

Page End

8

Print ISSN

2735-3109

Online ISSN

2735-3117

Link

https://aumj.journals.ekb.eg/article_393520.html

Detail API

http://journals.ekb.eg?_action=service&article_code=393520

Order

1

Type

Original Article

Type Code

2,278

Publication Type

Journal

Publication Title

Aswan University Medical Journal

Publication Link

https://aumj.journals.ekb.eg/

MainTitle

What is the difference in intraoperative complications between using cannulated screws and dynamic hip screws for fixation of femoral neck fracture?

Details

Type

Article

Created At

29 Mar 2025