Abstract

In order to improve the seismic behavior of reinforced concrete (RC) shear walls in high-rise structures, this research recommends employing an embedded cold-formed steel section (ECFS) composite wall. In order to determine how well composite shear walls withstand seismic activity, a battery of tests was run on four different specimens: two specimens with embedded CFS composite walls, one normal RC walls, and one cold formed steel bracing frame (CFSB-F). Specifically. A discussion was held regarding the experimental behavior of test specimens, covering topics such as load-deformation characteristics, damage development, energy dissipation, stiffness, failure mode, and ductility. As a result of the findings, it appears that composite shear walls that incorporate cold-formed steel have greatly improved lateral load can be reached over conventual wall by about 178 %, also Significantly enhancing stiffness of wall, and improvement in energy dissipation capacities by 16 %. Result showed good stability and performance of the composite shear wall with seismic loads in deformation capacity. Additionally, it was shown that crushing concrete could be reduced effectively. The maximum lateral load capacity was predicted using the Chinese Code for Design of Composite Structures. The comparison indicates a strong correlation between the test results and the estimated findings.

DOI

10.21608/ejchem.2024.312311.10193

Keywords

Composite shear walls, Encased R-C walls, Quasi-static load, Cold-formed Steel, skeleton curves

Authors

First Name

Mohamed

Last Name

Abd-el-wahed

MiddleName

Fekry

Affiliation

Faculty of Engineering-Mataria, Helwan University, Egypt

Email

engfekry89@gmail.com

City

-

Orcid

0009-0009-1078-3524

First Name

Mohamed

Last Name

Yehia

MiddleName

Mohamed

Affiliation

Faculty of Engineering-Mataria, Helwan University, Egypt

Email

m_yahia74@hotmail.com

City

cairo

Orcid

-

First Name

Sameh

Last Name

Gaawan

MiddleName

Moustafa

Affiliation

Faculty of Engineering-Mataria, Helwan University, Egypt

Email

sameh.gaawan@dar.com

City

cairo

Orcid

-

Volume

68

Article Issue

5

Related Issue

54251

Issue Date

2025-05-01

Receive Date

2024-08-14

Publish Date

2025-05-01

Print ISSN

0449-2285

Online ISSN

2357-0245

Link

https://ejchem.journals.ekb.eg/article_380490.html

Detail API

http://journals.ekb.eg?_action=service&article_code=380490

Order

380,490

Type

Original Article

Type Code

297

Publication Type

Journal

Publication Title

Egyptian Journal of Chemistry

Publication Link

https://ejchem.journals.ekb.eg/

MainTitle

Enhancing Seismic Efficiency of Composite Steel Shear Walls Using Encased C-Shape Cold-Formed Steel

Details

Type

Article

Created At

09 Mar 2025