Abstract

Objectives
There are several methods to manage an aseptic nonunited fracture femur over a dynamized interlocking nail. The aim of this study is to report and evaluate the outcome of plate augmentation in the management of aseptic nonunited femoral fractures fixed by a dynamized intramedullary nail.
Patients and methods
This prospective study included 17 patients (10 male and seven females) with an aseptic nonunited fracture femur over a dynamized intramedullary locked nail. Patients’ ages varied from 27 to 65 years, with a mean age of 45.5 years. All patients were managed by augmenting the fracture site by plate fixation, and an autograft was used in five patients.
Results
All our patients achieved painless unaided full weight bearing within 5 months (mean duration 15 months). The complete union was achieved in all patients, which was radiologically evident at a mean duration of 16 (ranging from 14 to 22 months). Complications occurred in two (11.7%) cases: one experienced postoperative hematoma, and the experienced from 1.5-cm limb shortening.
Conclusion
Plate augmentation is a reliable procedure for the management of aseptic nonunited femoral fractures fixed by a dynamized intramedullary nail.

DOI

10.4103/1110-1148.319028

Keywords

Interlocking Nail, nonunited femur, plate augmentation

Authors

First Name

Mohamed

Last Name

Fadel

MiddleName

H.

Affiliation

-

Email

mohfadel2007@hotmail.com

City

-

Orcid

-

First Name

Ahmed

Last Name

Ramy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mohammed

Last Name

Hashem

MiddleName

H.

Affiliation

-

Email

mohammedhashem@yahoo.com

City

-

Orcid

-

Volume

54

Article Issue

4

Related Issue

53899

Issue Date

2019-10-01

Publish Date

2019-10-01

Page Start

330

Page End

334

Print ISSN

1110-1148

Online ISSN

2090-9926

Link

https://eoj.journals.ekb.eg/article_412536.html

Detail API

http://journals.ekb.eg?_action=service&article_code=412536

Order

412,536

Publication Type

Journal

Publication Title

The Egyptian Orthopaedic Journal

Publication Link

https://eoj.journals.ekb.eg/

MainTitle

Plate augmentation in aseptic nonunited femoral fractures fixed by dynamized intramedullary nail

Details

Type

Article

Created At

25 Feb 2025