Beta
409809

Repair of pars interarticularis defect using a U-shaped rod–screw construct

Article

Last updated: 08 Feb 2025

Subjects

-

Tags

-

Abstract

Study design
Retrospective study.
Aim
To evaluate the efficacy of pars repair using pedicle screws connected with a U-shaped rod in the treatment of traumatic pars defect of the lower lumbar spine after failed conservative treatment.
Materials and methods
Eighteen patients with traumatic pars defect were managed from 2004 to 2009 by pars repair using two pedicle screws inserted into the involved vertebra and connected by a U-shaped rod passing under a spinous process and tightened after careful defect debridement and grafting. An MRI was performed to exclude adjacent disc degeneration. The patients were followed up using plain radiographs, in anteroposterior, lateral and oblique views. A computed tomography scan was performed to ensure pars healing.
Results
All patients had bilateral traumatic pars defect; their ages ranged from 16 to 27 years. Follow-up ranged from 24 to 53 months. Fourteen patients showed improved symptoms and returned to activity with full range of motion by the end of the sixth postoperative month. Two patients developed radicular pain; one showed complete improvement in the seventh week, whereas the other required revision. Two patients showed pseudoarthrosis and persistent pain that required revision with posterior lumbar interbody fusion.
Conclusion
This technique is an easy, effective technique of short operative duration with the advantage of nonviolation of the neural canal, no requirement for postoperative bracing and safe return to activity by the end of the sixth month, with no requirement for further fusion.

DOI

10.7123/01.EOJ.0000417984.02976.95

Keywords

Bone scan, Debridement, Pars defect, pedicle

Authors

First Name

Ahmed

Last Name

ElBadrawi

MiddleName

M.

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Mohamed

Last Name

ElSayed

MiddleName

N.

Affiliation

-

Email

-

City

-

Orcid

-

Volume

47

Article Issue

3

Related Issue

53580

Issue Date

2012-09-01

Publish Date

2012-09-01

Page Start

285

Page End

288

Print ISSN

1110-1148

Online ISSN

2090-9926

Link

https://eoj.journals.ekb.eg/article_409809.html

Detail API

http://journals.ekb.eg?_action=service&article_code=409809

Order

409,809

Publication Type

Journal

Publication Title

The Egyptian Orthopaedic Journal

Publication Link

https://eoj.journals.ekb.eg/

MainTitle

Repair of pars interarticularis defect using a U-shaped rod–screw construct

Details

Type

Article

Created At

08 Feb 2025