Beta
405828

Different Grey scale and Color Doppler Ultrasonographic Fetal Parameters in Prediction of Fetal Lung Maturity and its correlation with Neonatal Outcome

Article

Last updated: 20 Jan 2025

Subjects

-

Tags

Diagnostic Radiology.
Obstetrics and Gynecology.

Abstract

Background: Several methods were presented to estimate fetal lung maturity (FLM), including the lecithin/sphingomyelin ratio measurement, the phosphatidylglycerol existence or deficiency, and the lamellar body count in amniotic fluid (AF). However, all of these methods necessitate amniocentesis, which is an invasive process. Non-invasive ultrasound (US) methods have been studied to predict FLM.
Objectives: This study objective was to assess the various grey scale and color doppler US parameters accuracy and to identify the most sensitive and specific parameter as a non-invasive approach for predicting FLM.
Patients and methods: This prospective study was conducted on 100 pregnant women, aged 18 to 37 years old, who were experiencing a normal singleton pregnancy with a viable fetus and routine fetal surveillance between 34 and 40 weeks of gestation. All patients were investigated to: History taking, sonographic assessment, conventional 2D US, Epiphyseal ossification centers (EOC), placental grading, AF index and free-floating particles, thalamus echogenicity, fetal lung echogenicity, and doppler examination.
Results: Ultrasound parameters we found that EOC of the tibia has the highest accuracy 94% followed by EOC of the femur with accuracy 92 % then free-floating particles presence in AF with accuracy 83% and thalamic echogenicity with accuracy 80% and the least accuracy was for humerous OC 54% and lung echogenicity 45%. In concerning to doppler indices we noticed that Main pulmonary artery acceleration time / ejection time (MPA AT/ET) ratio cutoff value of 0. 295 showed the highest accuracy 94. 9% followed by Middle cerebral artery resistive index (MCA RI), Umbilical artery pulsatility index (UA PI), Umbilical artery resistive index (UA RI) and Main pulmonary artery resistive index (MPA RI) respectively.
Conclusions: Utilizing US and doppler to assess FLM is helpful. However, no single parameter alone could demonstrate definite sign of fetal lung maturity.

DOI

10.21608/svuijm.2025.323709.2045

Keywords

ultrasonographic, Color Doppler, Fetal Parameters, Fetal lung maturity, Neonatal Outcome

Authors

First Name

Reham Galal

Last Name

Fasad

MiddleName

-

Affiliation

Radiodiagnosis Department, Faculty of Medicine, Tanta University, Tanta, Egypt

Email

reroriri@yahoo.com

City

Kfr eldawar

Orcid

-

First Name

Mohamad Fouad

Last Name

Sherif

MiddleName

-

Affiliation

Radiodiagnosis Department, Faculty of Medicine, Tanta University, Tanta, Egypt

Email

-

City

-

Orcid

-

First Name

Mostafa Zein Elabdin

Last Name

Mostafa

MiddleName

-

Affiliation

Obstetrics & Gynecology Department, Faculty of Medicine, Tanta University, Tanta, Egypt

Email

-

City

-

Orcid

-

First Name

Yosra Fouad

Last Name

Rashad

MiddleName

-

Affiliation

Radiodiagnosis Department, Faculty of Medicine, Tanta University, Tanta, Egypt

Email

-

City

-

Orcid

-

Volume

8

Article Issue

1

Related Issue

52988

Issue Date

2025-01-01

Receive Date

2024-12-14

Publish Date

2025-01-01

Page Start

55

Page End

70

Print ISSN

2735-427X

Online ISSN

2636-3402

Link

https://svuijm.journals.ekb.eg/article_405828.html

Detail API

http://journals.ekb.eg?_action=service&article_code=405828

Order

405,828

Type

Original research articles

Type Code

1,520

Publication Type

Journal

Publication Title

SVU-International Journal of Medical Sciences

Publication Link

https://svuijm.journals.ekb.eg/

MainTitle

Different Grey scale and Color Doppler Ultrasonographic Fetal Parameters in Prediction of Fetal Lung Maturity and its correlation with Neonatal Outcome

Details

Type

Article

Created At

20 Jan 2025