Beta
402149

Clinical assessment of the biting force in patients receiving modified and unmodified Bre-Flex aesthetic clasp CAD/CAM dentures: a randomized cross-over study

Article

Last updated: 07 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

The study was performed to assess the magnitude of biting force
For patients with two types of cad cam esthetic clasp dentures (modified and unmodified Bre-Flex denture base material).
Methodology: A total of five mandibular Kennedy class I partially edentulous male patients were included in this study. All patients received two successive esthetic clasp removable partial dentures (modified and unmodified Bre-Flex). For each patient the mean biting force was measured at the time of insertion and after 2 months of using the dentures with one-month tissue rest between the two types.
Results: One way ANOVA test was conducted to assess the significance between the two RPD types at time of insertion and after two months of use, the data revealed that the mean biting force for the modified group at time of insertion was 0.1172+0.135 and after two months was 0.1264+0.3 with no significant differences. The mean biting force for the unmodified group at time of insertion was 0.108+0.0924 and after two months was 0.1236+0.104 with P value 1.00, indicating no significant differences. There were no statistically significant differences between the two groups in relation to the patient's maximum biting force. (P value was 0.22).
Conclusion: For each group (modified and unmodified partial denture base materials), there was no significant difference regarding the mean biting force at time of insertion and after two months of use. There were no statistically significant differences in relation to the patient's maximum active biting force between the two groups. (P value was 0.22).

DOI

10.21608/edj.2024.339544.3277

Keywords

Removable Partial Denture, BRE-Flex, maximum biting force

Authors

First Name

eman

Last Name

mohammed

MiddleName

husseiny

Affiliation

Assistant Professor, Removable Prosthodontics Department, Faculty of Oral and Dental Medicine and Surgery, Zagazig Univeristey

Email

eman_proth@yahoo.com

City

zagazig

Orcid

0000-0002-6239-4696

First Name

sara

Last Name

mohamed

MiddleName

zaky

Affiliation

Assistant Professor, Removable Prosthodontic Department, Faculty Of Dentistry, Suez Canal University

Email

sara_zaki@dent.suez.edu.eg

City

-

Orcid

0000-0002-3147-2225

First Name

HUSSEIN

Last Name

ISMAIL

MiddleName

-

Affiliation

Associate Professor, Removable Prosthodontics Department, Faculty of Oral and Dental Medicine and Surgery, Zagazig Univeristey

Email

tifamizo@gmail.com

City

-

Orcid

0000-0002-6258-8132

Volume

71

Article Issue

1

Related Issue

52688

Issue Date

2025-01-01

Receive Date

2024-11-26

Publish Date

2025-01-01

Page Start

721

Page End

731

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_402149.html

Detail API

http://journals.ekb.eg?_action=service&article_code=402149

Order

402,149

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Clinical assessment of the biting force in patients receiving modified and unmodified Bre-Flex aesthetic clasp CAD/CAM dentures: a randomized cross-over study

Details

Type

Article

Created At

07 Jan 2025