Beta
402139

Accuracy of Digital Impressions Obtained by Different Intraoral Scanners Compared with The Laboratory Scanner for Implants Placed in Partially Edentulous Mandible: An In Vitro St

Article

Last updated: 07 Jan 2025

Subjects

-

Tags

Removable Prosthodontics

Abstract

Aim: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (Medit i700, 3Shape TRIOS 4 and Carestream CS3600) versus the desktop lab scanner for implants placed in Kennedy class II partially edentulous mandible.
Methodology: A 3D-printed resin cast simulating a Kennedy Class II mandibular arch with two implants, in the first premolar and first molar regions, was used. Each scan body and the mucosal part of the edentulous area were scanned once by a laboratory scanner to establish a reference standard. Then, they were scanned five times with each intraoral scanner. The scans were compared using Geomagic Control X software to measure the root mean square (RMS) deviation. Statistical tests were conducted to assess and compare trueness and precision between and within groups.
Results: For trueness, the One-Way ANOVA test showed no statistically significant differences among the three groups for anterior scan body, posterior scan body, and mucosal part (P-values: 0.14, 0.45, and 0.40 respectively). For precision, significant differences were found in the posterior scan body (P=0.03) and mucosal part (P=0.004), with the TRIOS 4 scanner demonstrating the highest precision. No significant differences between the three intraoral scanners were observed for the anterior scan body part (P=0.09).
Conclusions: The study revealed that intraoral scanners exhibit varying precision for different anatomical regions, despite comparable trueness. This underscores the necessity of carefully considering scanner selection based on clinical requirements to guarantee accurate digital impressions and optimal treatment outcomes.

DOI

10.21608/edj.2024.329328.3236

Keywords

Implants, Trueness, Precision, Intraoral Scanners, Kennedy class II

Authors

First Name

Omar

Last Name

Abdelrahman

MiddleName

Sherif

Affiliation

Master Candidate, Master Implantology, Faculty of Dentistry, Cairo University.

Email

closa555@hotmail.com

City

Cairo

Orcid

0009-0006-2098-0079

First Name

Amal

Last Name

Kaddah

MiddleName

Fathy

Affiliation

Professor, Department of Prosthodontics, Faculty of Dentistry, Cairo University.

Email

amalkaddah@yahoo.com

City

Cairo

Orcid

0000-0002-2128-6162

First Name

Mohamed

Last Name

Abdallah

MiddleName

Farouk

Affiliation

Professor, Department of Prosthodontics, Faculty of Dentistry, Cairo University and Galala University.

Email

mohamed.abdalla@dentistry.cu.edu.eg

City

Cairo

Orcid

0000-0002-6617-9379

First Name

Nermeen

Last Name

Hassan

MiddleName

Ahmed

Affiliation

Lecturer, Department of Prosthodontics, Faculty of Dentistry, Cairo University.

Email

nermeen.hassan@dentistry.cu.edu.eg

City

Cairo

Orcid

0000-0002-5393-9607

Volume

71

Article Issue

1

Related Issue

52688

Issue Date

2025-01-01

Receive Date

2024-10-21

Publish Date

2025-01-01

Page Start

611

Page End

618

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_402139.html

Detail API

http://journals.ekb.eg?_action=service&article_code=402139

Order

402,139

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Accuracy of Digital Impressions Obtained by Different Intraoral Scanners Compared with The Laboratory Scanner for Implants Placed in Partially Edentulous Mandible: An In Vitro Study.

Details

Type

Article

Created At

07 Jan 2025