401053

Accuracy of Proplan CMF R 3.0.1 versus Planmeca Romexis R 6.4.1; in the fabrication of occlusal repositioning splints for Orthognathic surgery; Randomized controlled trial

Article

Last updated: 07 Jan 2025

Subjects

-

Tags

Oral and Maxillofacial Surgery

Abstract

Objectives: This study compared the accuracy of two software programs, Proplan CMF R 3.0.1 and Planmeca Romexis R 6.4.1, for fabricating occlusal repositioning wafers for bimaxillary orthognathic surgery.

Materials and Methods: Our research was conducted on 18 patients with skeletal deformities. Patients were randomly distributed into two groups: the control group, where 9 patients were planned by Proplan CMF R 3.0.1; and the study group, where 9 were planned by Planmeca R 6.4.1. All the patients underwent bimaxillary orthognathic surgery. Each patient received 2 CT scans preoperatively and 1 month postoperatively. Materialize 3-matic software was used to identify discrepancies between the virtual treatment plan and the outcome by superimposing the planned STL model with the postoperative one.

Results: The deviations measured with Romexis were slightly higher than those with Proplan. However, the results had no significant differences (p > 0.05). Both programs effectively fabricated splints accurately enough to transfer the virtual planning to the operation theater. The mean differences between the planned and postoperative positions of the maxilla and mandible were 0.37 and 0.48 mm.

Conclusion: This study supports the accuracy of both software programs (Proplan and Romexis) for splint fabrication for bimaxillary orthognathic surgery. However, further research is needed to refine software algorithms to reduce the observed minor variations.

DOI

10.21608/edj.2024.327122.3226

Keywords

Bimaxillary Orthognathic Surgery, Planmeca Romexis R 6.4.1, Proplan CMF R 3.0.1, Materialise 3-Matic, Repositioning Splints

Authors

First Name

Amr

Last Name

Ghanem

MiddleName

Amin

Affiliation

Professor, Department of Oral and Maxillofacial surgery, Faculty of Dentistry, British University in Egypt, Cairo, Egypt

Email

amr.amin@bue.edu.eg

City

cairo

Orcid

0000-0002-0876-2910

First Name

Ahmed

Last Name

El Sokkary

MiddleName

Mohamed Sadek

Affiliation

Instructor, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.

Email

ahmed.sadek@dent.asu.edu.eg

City

Cairo

Orcid

0009-0007-9501-9298

First Name

Mohamed

Last Name

Nagy

MiddleName

Mahmoud Mohamed

Affiliation

Instructor, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, the British University in Egypt, Cairo, Egypt.

Email

mohamed.nagy@bue.edu.eg

City

-

Orcid

0009-0008-3453-6424

First Name

Mohib

Last Name

Girgis

MiddleName

Sami Labib

Affiliation

Instructor, Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, the British University in Egypt, Cairo, Egypt.

Email

mohib.sami2011@gmail.com

City

Cairo

Orcid

0009-0004-2413-0763

Volume

71

Article Issue

1

Related Issue

52547

Issue Date

2025-01-01

Receive Date

2024-10-09

Publish Date

2025-01-01

Page Start

165

Page End

172

Print ISSN

0070-9484

Online ISSN

2090-2360

Link

https://edj.journals.ekb.eg/article_401053.html

Detail API

http://journals.ekb.eg?_action=service&article_code=401053

Order

401,053

Type

Original Article

Type Code

254

Publication Type

Journal

Publication Title

Egyptian Dental Journal

Publication Link

https://edj.journals.ekb.eg/

MainTitle

Accuracy of Proplan CMF R 3.0.1 versus Planmeca Romexis R 6.4.1; in the fabrication of occlusal repositioning splints for Orthognathic surgery; Randomized controlled trial

Details

Type

Article

Created At

07 Jan 2025