Beta
377479

EVALUATION OF TWO DIFFERENT ATTACHMENT SYSTEMS IN MANDIBULAR OVERDENTURES RETAINED WITH TWO INCLINED IMPLANTS (A RANDOMIZED CONTROLLED CLINICAL TRIAL)

Article

Last updated: 30 Dec 2024

Subjects

-

Tags

Prosthodontics

Abstract

Introduction: Selection of the proper overdenture attachment system can be challenging for the prosthodontist if there is a lack of implant parallelism.
Objectives: The study aimed to radiographically assess the influence of two distinct attachment systems on marginal bone loss (MBL) around a pair of 30-degree divergent implants retaining mandibular overdentures.
Materials and Methods: The study involved 22 fully edentulous patients who underwent a prospective randomized controlled trial (RCT). In this trial, each patient received a pair of implants tilted at a 15° angle from the vertical axis, bilaterally placed in the canine regions using a minimally invasive flapless surgical technique. The participants were evenly divided into two groups: Group N (n = 11), which received mandibular overdentures with angled Novaloc attachments, and Group L (n=11), which received mandibular overdentures with Locator attachments. The evaluation of MBL was conducted at three time points: baseline (prosthetic loading), 3 months, and 12 months after prosthetic loading.
Results: By the end of 12 months, the mean values of MBL did not exceed 1.5 mm in both groups. The mean values of MBL were greater in group N than in group L with a statistically significant difference.
Conclusion: The Locator attachment may be viewed as superior to the angled Novaloc attachments when it comes to peri-implant bone loss around 15° distally inclined implants used to retain mandibular complete overdentures. Nevertheless, the bone loss with angled Novaloc attachments remains within clinically acceptable limits.

DOI

10.21608/adjalexu.2024.247759.1443

Keywords

overdenture, inclined implants, Novaloc, locator, attachment

Authors

First Name

Haitham

Last Name

Hassan

MiddleName

-

Affiliation

Assistant lecturer, Prosthodontics Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt

Email

haithamrossonero@gmail.com

City

Alexandria

Orcid

0000-0001-5154-0814

First Name

Ahmad

Last Name

El Shimy

MiddleName

-

Affiliation

Professor, Department of Removable Prosthodontics, Faculty of Dentistry, Alexandria University, Egypt

Email

ahmadalshimy@yahoo.com

City

Alexandria

Orcid

0000-0002-4360-3579

First Name

Tarek

Last Name

Abdalazim

MiddleName

Sahry

Affiliation

Assistant professor, Department of Oral Medicine, Periodontology, Oral Diagnosis and Radiology

Email

tareksahry@gmail.com

City

Alexandria

Orcid

-

First Name

Kenda

Last Name

Hanno

MiddleName

Hisham

Affiliation

Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Email

kendahanoo@gmail.com

City

Alexandria

Orcid

0000-0002-1250-9897

Related Issue

-2

Receive Date

2023-11-12

Publish Date

2024-08-31

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_377479.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=377479

Order

1

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

EVALUATION OF TWO DIFFERENT ATTACHMENT SYSTEMS IN MANDIBULAR OVERDENTURES RETAINED WITH TWO INCLINED IMPLANTS (A RANDOMIZED CONTROLLED CLINICAL TRIAL)

Details

Type

Article

Created At

30 Dec 2024