Abstract

Introduction: Once teeth are extracted, the alveolar bone with the labial bone plate reduction occurs as a consequence of the absence of blood flow. The socket-shield technique) SST) was introduced to end these consequences.
Objectives: Our goal was to compare between the conventional approach and the SST perspectives; clinical and radiographical.
Materials and Methods: 20 individuals were parted into 2 groups; the study group: The (SST) with immediate loading was applied 10 implants in the anterior maxilla. The control group: 10 implants were instantly placed using immediate implant placement (IIP) along with the immediate loading. For both groups, CBCT-scans were pre-operatively evaluated and 6 months period for evaluating the dimensional changes within the labial bone plates including both the vertical and horizontal bone loss (VBL, HBL), measuring of clinical attachment loss (CAL), the dental implant stability quotients (DISQs) and the pink esthetic scores (PES),
Results: The mean Dental Implant Stability (DISQ) was 77.92+2.44 and 75.14+2.34 in control and study groups respectively 6 months postoperatively, the average HBL bone level 6 months postoperative in Group 1 was 6.88+0.97mm, and in Group 2 was 6.74+0.93mm. While mean VBL level after 6 months of follow up in Groups 1 and 2 was 0.93+0.57mm, and 1.55+0.85mm respectively. The mean PES in Group 1 was 12.10+0.57 after 6 months, while in Group 2 was 7.80+1.14. The mean CAL 6 months Post-operatively in Group 1 and Group 2 was 0.90+0.57mm and 1.50+0.85mm respectively
Conclusions: The technique of socket-shield was conserved the labial root part

DOI

10.21608/adjalexu.2023.192795.1351

Keywords

immediate implants, extraction socket, immediate loading, Socket shield technique

Authors

First Name

Mohamed

Last Name

Shehata

MiddleName

Mohamed

Affiliation

Oral and Maxillofacial Surgery, Faculty of Dentistry, Alexandria University

Email

hamoshehata@gmail.com

City

Alexandria

Orcid

-

First Name

Adham

Last Name

Alashwah

MiddleName

Ahmed

Affiliation

Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt

Email

adhamelashwah@gmail.com

City

Alexandria

Orcid

-

First Name

Rania

Last Name

Ahmed

MiddleName

A

Affiliation

Assistant Professor, Oral Medicine and Periodontology, Faculty of Dentistry, Alexandria University, Alexandria City, Egypt

Email

raniaperio@hotmail.com

City

Alexandria

Orcid

raniaperio@hotmail.c

First Name

Ahmed

Last Name

Ahmed

MiddleName

Osama

Affiliation

Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Alexandria University, Egypt.

Email

drahmed.sweedan@gmail.com

City

alex

Orcid

-

Volume

49

Article Issue

2

Related Issue

49284

Issue Date

2024-08-01

Receive Date

2023-02-08

Publish Date

2024-08-01

Page Start

66

Page End

72

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_353433.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=353433

Order

9

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

EVALUATION OF IMMEDIATE LOADED IMPLANTS PLACED USING THE SOCKET SHIELD TECHNIQUE IN THE ESTHETIC ZONE (A RANDOMIZED CONTROLLED CLINICAL TRIAL)

Details

Type

Article

Created At

30 Dec 2024