Abstract

Introduction: Patients with a traditional denture may have difficulty chewing because of the absence of retention. Recently, using two un-splinted implants assisted overdenture to overcome the retention problem. But still Acrylic material has problems; such as lowers impact, fatigue strengths, and fracture. Reinforcement of acrylic denture base to avoid fracture by a variety of materials such as; Metal reinforcement, fillers like carbon fiber, and Poly-Ether-Ether-Ketone (PEEK) is frequently utilized in dentistry and is seen as a viable alternative to traditional materials.
Aim of the study: Compare between Two different denture base reinforcement materials (CoCr) and (PEEK) in comparison to acrylic dentures on strain around two implant-assisted mandibular overdenture and on ridge area.
Materials and methods: 3 epoxy models were used with two implants placed at the canine region. 8 mandibular overdenture were constructed for each group; (group A) Acrylic overdenture without reinforcement, for (group B) and (group c) acrylic overdenture were reinforcement by (CoCr, PEEK) respectively. Six linear strain gauges were used at the mesial and distal of each implant, and under the lower second molars bilaterally. Strain measurements were taken under central and unilateral loading around the two implants and on the ridge regions.
Results: No significant difference between all groups upon application of central load 100N on ridges. However, group C showed lower strain values upon application of central and unilateral loading 100N.
Conclusion: PEEK reinforcement material showed less strain values with favorable stress distribution when compared to Acrylic and cobalt chromium reinforcement material for implant-assisted mandibular overdenture.

DOI

10.21608/adjalexu.2022.150941.1299

Keywords

Denture base reinforcement, Cobalt-Chromium alloy, PEEK, Implant assisted overdenture, ball and socket attachment

Authors

First Name

Zaid

Last Name

Alganabi

MiddleName

-

Affiliation

Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Egypt

Email

sales1herbal@gmail.com

City

-

Orcid

-

First Name

Elsayed

Last Name

Nawar

MiddleName

Abdul khader

Affiliation

Prosthodontics, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Egypt

Email

elsayed.nawar@alexu.edu.eg

City

-

Orcid

-

First Name

Mona

Last Name

Saad

MiddleName

Sabry

Affiliation

Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Egypt

Email

mon_sabry2@yahoo.com

City

-

Orcid

0000-0001-8949-0840

Volume

48

Article Issue

3

Related Issue

44498

Issue Date

2023-12-01

Receive Date

2022-07-18

Publish Date

2023-12-01

Page Start

143

Page End

151

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_327220.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=327220

Order

5

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

STRAIN ASSESSMENT OF COBALT CHROMIUM VERSUS POLY-ETHER-ETHER-KETONE FOR REINFORCING MANDIBULAR OVERDENTURE ASSISTED BY TWO IMPLANTS (A COMPARATIVE IN-VITRO STUDY)

Details

Type

Article

Created At

30 Dec 2024