Abstract

ABSTRACT
Background: Splinting of multiple implants during impression with the most accurate material to reproduce their intraoral relationship is deemed necessary for achieving passively fitting prosthesis.
Aim of the study: To assess positional accuracy of multiimplant impressions for completely edentulous arches obtained by a 3D printed splint and compare the results obtained with those obtained with conventional methods.
Material and methods: One mandibular epoxy model with 4 parallel implants was used as master reference model. A total of 24 (n=24) open tray impressions were done using a custom-made tray and were poured in dental stone. Eight impressions were done with 3D printed splint (group I), 8 were done with the conventional splinting method (group II), and 8 were done with sectional splinting method (group III). Four impression posts were attached to each cast, and all casts were scanned using a desktop scanner. Surface scans for the 3 groups were superimposed with the scan of the master reference model. The positional accuracy of each post was compared with the reference model to assess positional deviations.
Results: Models of group I showed lower positional deviation compared to other groups. No statistically significant differences were found between the 3 impression techniques regarding positional accuracy of the implants.
Conclusion: 3D printed splint method can be used as an alternative to conventional splinting techniques.
Keywords: Multiimplant impression; Splinting technique; 3D printed splint.

DOI

10.21608/adjalexu.2022.150446.1297

Keywords

Multi-implant impression, Splinting technique, 3D splint

Authors

First Name

Ahmed

Last Name

Awaad

MiddleName

Ibrahim

Affiliation

prosthdontics department, faculty of dentistry, alexandria university.

Email

a7med.3waad9999@gmail.com

City

-

Orcid

0000-0002-8985-0209

First Name

Akram

Last Name

Neena

MiddleName

-

Affiliation

Assistant lecturer of Removable Prosthodontics, Faculty of Dentistry, Alexandria University

Email

akram.morshedy@alexu.edu.eg

City

-

Orcid

0000-0001-7534-9635

First Name

Faten

Last Name

Abbas

MiddleName

Salah Eldin

Affiliation

Prosthodontics Department, Faculty of Dentistry, Alexandria University, Egypt

Email

faten_salah@hotmail.com

City

Alexandria

Orcid

-

Volume

48

Article Issue

3

Related Issue

44498

Issue Date

2023-12-01

Receive Date

2022-07-30

Publish Date

2023-12-01

Page Start

138

Page End

142

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_327219.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=327219

Order

4

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

DIGITAL ASSESSMENT OF POSITIONAL ACCURACY OF DIFFERENT SPLINTING MULTIIMPLANT IMPRESSION TECHNIQUES: AN IN VITRO COMPARATIVE STUDY

Details

Type

Article

Created At

30 Dec 2024