Abstract

Introduction: Strain around labially inclined implants retaining mandibular overdentures with ti–si attachments is still unclear.
Objective: To evaluate strain around labially inclined implants retaining mandibular overdentures by using ti-si attachments
Material and methods: Two mandibular epoxy models were constructed. Resilient soft lining material was used to simulate resilient edentulous ridge mucosa. The epoxy models were scanned. Two dummy implants were inserted in canine regions using CAD CAM surgical guides with the following degrees of labial inclinations: group A (control); 0°, group B; 17.5°. Mandibular overdentures were constructed over the models and connected to the models with Ti Si attachments with retentions Sil 400g/4 Newton. Strain measurements were performed under central and unilateral loading using Universal testing machine.
Results: In a comparison of group A and group B under central loading, no significant difference of microstrain was detected around the implants. Microstrain around two labially inclined implants increase as labial implant inclination increases. The increased strains with inclined implants became more evident with unilateral loading than central loading. Stresses were recorded at lingual, and less stresses were recorded at distal for both groups.
Conclusions: In both groups vertical and inclined implant under central and unilateral loading, the highest microstrain was recorded at the lingual and mesial sides of the implant. While the lowest was recorded at distal of the implant.
In comparing the two groups no significant difference was found with central loading while, with unilateral loading significant increase in microstrain was recorded in the inclined implants group.

DOI

10.21608/adjalexu.2022.116200.1247

Keywords

Labial Implant Inclination, Strain, Ti Si, Snap Attachments, Retention Sil Ti Si

Authors

First Name

Dina

Last Name

Abou Warda

MiddleName

Ahmed

Affiliation

Instructor in Prosthodontics, Faculty of Dentistry, Pharos University, Alexandria, Egypt

Email

dinawarda395@gmail.com

City

Alexandria

Orcid

-

First Name

ahlam

Last Name

sharkawy

MiddleName

-

Affiliation

professor at prosthodontic department, faculty of dentistry, Alexandria university, Alexandria, Egypt.

Email

drahlamsharkawy@yahoo.com

City

alexandria

Orcid

-

First Name

Ahmed

Last Name

Abdel Hakim

MiddleName

Adel

Affiliation

Professor of Removable Prosthodontics, and Dean of Faculty of dentistry, Alexandria University, Egypt

Email

ahmedaahakim@yahoo.com

City

Alexandria

Orcid

-

First Name

Fayza

Last Name

Alabbassy

MiddleName

Hassan

Affiliation

Dental Biomaterials Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Email

fayza_alabbassy@yahoo.com

City

Alexandria

Orcid

-

Volume

48

Article Issue

1

Related Issue

40501

Issue Date

2023-04-01

Receive Date

2022-02-03

Publish Date

2023-04-01

Page Start

181

Page End

187

Print ISSN

1110-015X

Online ISSN

2536-9156

Link

https://adjalexu.journals.ekb.eg/article_292669.html

Detail API

https://adjalexu.journals.ekb.eg/service?article_code=292669

Order

9

Type

Original Article

Type Code

1,057

Publication Type

Journal

Publication Title

Alexandria Dental Journal

Publication Link

https://adjalexu.journals.ekb.eg/

MainTitle

EVALUATION OF STRAIN AROUND LABIALLY INCLINED IMPLANTS RETAINING MANDIBULAR OVERDENTURES WITH TITANIUM-SILICONE ATTACHMENTS (COMPARATIVE IN-VITRO STUDY)

Details

Type

Article

Created At

30 Dec 2024