Beta
371354

Automated MDCT Post-Processing Software for Aortic Annulus Parameters before Surgical Aortic Valve Replacement: Correlation with Operative Details

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Background: A comparative study between the automated MDCT post-processing to measure the aortic annulus parame-ters before surgical aortic valve replacement and intra-opera-tive aortic annulus sizing was done. Aim of Study: To compare the accuracy of pre-operative automated Fuji software synapse 3D tools with the surgical de-tails of aortic valve replacement, regarding the aortic annulus parameters and distance between the aortic annulus and the coronary ostia. Patients and Methods: Our study included 168 patients who presented with significant aortic valve disease. Surgical aortic valve replacement was the treatment of choice. The CT images were post-processed using automated Fuji software synapse 3D tools . Intraoperative aortic valve annulus sizing was done. Results: The mean age of our patients was from 28 to 72 years (mean 54.6±7.2 years). There was a statistically signifi-cant positive correlation between aortic calcification grading and AVA by CT examination. There was excellent agreement for annulus effective and mean diameters (ICC: 0.939 & ICC: 0.881 respectively), good agreement for maximum diameter (ICC: 0.751, 95% CI: (0.479-0.850), poor agreement for mini-mum diameter & annulus area. The correlation of left coronary artery ostium height and right coronary artery ostium height was considered acceptable with a p-value of 0.182 and 0.617 respectively. Conclusion: MDCT is used as a complementary method in pre-procedural planning of aortic valve surgery as it is more accurate in the assessment of aortic valve anatomy, calcifica-tion, and aortic annulus sizing. The automated post-processing software tools provide important clinical application in the management of patients undergoing surgical aortic valve re-placement with reliable and reproducible aortic annulus meas-urements, thus reducing the post-procedural complications.

DOI

10.21608/mjcu.2024.371354

Authors

First Name

BASANT M. RAIEF MOSAAD, M.D.*

Last Name

EMAD H. ABDELDAYEM, M.D.*; HAZEM I. KORASHI, M.D.*; MOHAMED A. GAMAL, M.D.**

MiddleName

-

Affiliation

The Department of Radiology* and Cardiothoracic Surgery Department**, Faculty of Medicine, Ain Shams University

Email

-

City

-

Orcid

-

Volume

92

Article Issue

06

Related Issue

49610

Issue Date

2024-06-01

Receive Date

2024-08-01

Publish Date

2024-06-01

Page Start

497

Page End

504

Print ISSN

0045-3803

Online ISSN

2536-9806

Link

https://mjcu.journals.ekb.eg/article_371354.html

Detail API

https://mjcu.journals.ekb.eg/service?article_code=371354

Order

371,354

Type

Original Article

Type Code

263

Publication Type

Journal

Publication Title

The Medical Journal of Cairo University

Publication Link

https://mjcu.journals.ekb.eg/

MainTitle

Automated MDCT Post-Processing Software for Aortic Annulus Parameters before Surgical Aortic Valve Replacement: Correlation with Operative Details

Details

Type

Article

Created At

30 Dec 2024