Beta
341051

Impact of Different Grid Sizes and Different Dose Calculation Algorithms on Dosimetric Parameters forHead and Neck IMRT.

Article

Last updated: 01 Jan 2025

Subjects

-

Tags

-

Abstract

Purpose: study the dosimetric impact of grid size and dose calculation algorithm on the intensity modulated radiotherapy (IMRT) plans for head and neck (H&N) cancer cases. Method: IMRT plans were generated in the MONACO® treatment planning system (TPS). That supports calculations to different algorithms (Monte Carlo (MC) and pencil beam (PB)) for patients already treated for H&N cancer. Retrieve patients and recalculate the plans by changing between grid size (2, 3, 4, 5 mm) and algorithm (MC and PB) for each plan. Dosimetric parameters for planning target volume (PTV) are minimum, maximum, and mean doses, D5%, V95%, homogeneity index (HI), conformity index (CI), and gradient index (GI). For organs at risk (OARs) maximum dose (Dmax), mean dose (Dmean). For the volume of the whole body (WB) receiving 2 Gy (V2Gy) and 5 Gy (V5Gy).
Results: 11 patients were enrolled in this study for analysis. Regarding HI and CI, MC plans show better results than PB plans. Comparing algorithms at the same grid size shows significance (P-value < 0.05) in all PTV parameters (except Dmin and mGI). Comparing grid sizes shows significance in only Dmax, Dmean, D5%, V95%, and CI2.

DOI

10.21608/ejbbe.2024.233377.1065

Keywords

Dosimetric evaluation, grid size, Monte Carlo, Pencil Beam, IMRT

Authors

First Name

Alzahraa

Last Name

Ali

MiddleName

-

Affiliation

Physics Department, Faculty of Science, Benha University

Email

zahraa234ali@gmail.com

City

-

Orcid

-

First Name

Samira

Last Name

Sallam

MiddleName

Mohammed

Affiliation

Physics department, faculty of science, Benha University.

Email

samira.salam@fsc.bu.edu.eg

City

Benha

Orcid

-

First Name

Mahmoud

Last Name

Ahmed

MiddleName

Meselhy

Affiliation

radiation oncology departement national cancer institute

Email

mahmoud.meselhy@nci.cu.edu.eg

City

-

Orcid

0000-0001-6254-8387

First Name

Ehab

Last Name

Attalla

MiddleName

Marouf

Affiliation

Radiotherapy &amp;amp; Nuclear Medicine Dep.; National Cancer Institute ; Cairo university

Email

attalla.ehab@gmail.com

City

cairo

Orcid

-

First Name

Abdelfattah

Last Name

Mohamed

MiddleName

-

Affiliation

Physics Department, Faculty of Science, Benha University

Email

abdelfattah.mohamed@fsc.bu.edu.eg

City

-

Orcid

-

First Name

Mona

Last Name

Rshbek

MiddleName

-

Affiliation

Physics Department, Faculty of Science, Benha University

Email

mona.rshbek@fsc.bu.edu.eg

City

-

Orcid

-

Volume

25

Article Issue

1

Related Issue

46112

Issue Date

2024-12-01

Receive Date

2023-09-02

Publish Date

2024-02-01

Page Start

13

Page End

23

Print ISSN

1110-8525

Online ISSN

2357-0911

Link

https://ejbbe.journals.ekb.eg/article_341051.html

Detail API

https://ejbbe.journals.ekb.eg/service?article_code=341051

Order

341,051

Type

Original Article

Type Code

109

Publication Type

Journal

Publication Title

Egyptian Journal of Biomedical Engineering and Biophysics

Publication Link

https://ejbbe.journals.ekb.eg/

MainTitle

Impact of Different Grid Sizes and Different Dose Calculation Algorithms on Dosimetric Parameters forHead and Neck IMRT.

Details

Type

Article

Created At

30 Dec 2024