Radiobiological and dosimetric indices related effects of patient setup errors were evaluated for prostate patients treated using volumetric modulated arc therapy technique.
Materials and Methods:
Ten patients were treated and evaluated during the course of treatment. Each one was treated with 2 Gy for 39 fractions. The setup verification of each patient was determined using an electronic portal imaging device for 5 fractions during the treatment course. The mean of setup errors for those 5 fractions was calculated for each patient. Dose-Volume Histograms of the planning target volume, femoral heads, bladder and rectum were generated, and the conformity index, homogeneity index, tumor control probability, and normal tissue complication probability were determined.
The population random set-up errors were (3.61), (3.24), and (3.87) mm in vertical, longitudinal, and lateral directions respectively. Radiobiological indexes were evaluated witht and without inrtoduction of the random errors. In the original plan the average EUD in the VMAT plans was 77.59 Gy, and the average of TCP was 98.24%; but with the introduction of the errors, the average EUD became in the order of 60.24 Gy, while the average of TCP was in the order of 84.24%. Significant differences were observed between the two plans.

The dosimetric and biological impacts were evaluated and indicated that setup errors during VMAT treatments can lead to a non-significant change of conformity and homogeneity but can lead to changes in the dose distribution influencing the target volume coverage and altering the deliver dose to the organs at risk.

DOI

10.21608/ejbbe.2022.176331.1060

Keywords

Dosemtrical indices, Radiobiological indices, Setup errors, Systematic error, Randomized error

Authors

First Name

Asmaa

Last Name

Moustafa

MiddleName

-

Affiliation

Department of Nuclear Medicine and Oncology, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Email

asmaamoustafa482@yahoo.com

City

-

Orcid

-

First Name

Ehab

Last Name

Attalla

MiddleName

Marouf

Affiliation

Professor of medical physics at National Cancer Institute, Cairo University. Cairo, Egypt.

Email

e.marouf@cu.edu.eg

City

Giza

Orcid

0000-0003-4779-4445

First Name

S.M.

Last Name

EL-Sayed

MiddleName

-

Affiliation

Department of Nuclear Medicine and Oncology, Faculty of Medicine, Ain Shams University, Cairo, Egypt

Email

somaiametwall@yahoo.com

City

-

Orcid

-

First Name

Ibrahim

Last Name

Hassan

MiddleName

-

Affiliation

Physics Department, Faculty of Science, Ain Shams University, Cairo, Egypt

Email

ihseada@yahoo.com

City

-

Orcid

-

Volume

24

Article Issue

1

Related Issue

39408

Issue Date

2023-12-01

Receive Date

2022-12-12

Publish Date

2023-12-01

Page Start

13

Page End

30

Print ISSN

1110-8525

Online ISSN

2357-0911

Link

https://ejbbe.journals.ekb.eg/article_285774.html

Detail API

https://ejbbe.journals.ekb.eg/service?article_code=285774

Order

285,774

Type

Original Article

Type Code

109

Publication Type

Journal

Publication Title

Egyptian Journal of Biomedical Engineering and Biophysics

Publication Link

https://ejbbe.journals.ekb.eg/

MainTitle

Physical and Radiobiological Evaluation of Patient Setup Errors in the Radiotherapy Procedure for Prostate Cancer

Details

Type

Article

Created At

30 Dec 2024