Beta
380664

ASSESSMENT OF INTERNAL FIT OF CUSTOM-MADE POSTS FABRICATED BY OPTICAL IMPRESSION (AN IN-VITRO STUDY)

Article

Last updated: 05 Jan 2025

Subjects

-

Tags

Prosthodontics and dental biomaterials

Abstract

Aim: The aim of the study was to compare the internal fit of custom-made post fabricated by direct scanning of post space with indirect technique (Addition silicon).
Methodology: Twenty single rooted teeth were endodontically treated and prepared to depth 12 mm for receiving post and core restorations. The specimens were randomized into two equal groups: CAD/CAM PEEK post and core restorations for group I, were obtained by direct scanning intracanal. For group II polyvinylsiloxane impressions of the post space were scanned. Post and core restorations were milled and cemented on their respective teeth. All the twenty specimens were then sectioned horizontally, and the cement thickness was evaluated using a steromicroscope.
Results: The CAD/CAM post and core restoration fabricated by the direct scan approach had the least cement thickness and attained higher adaptation in comparison with conventional impression scanning technique within non-significant range.
Conclusions: Within the limitations of this study; CAD/CAM scanning methods to post fabricated from Polyetheretherketone, presented adequate internal adaptation to root canal within the accepted clinical range. Direct scanning is considered as an alternative to the conventional impression in fabrication of PEEK post and core restorations.

DOI

10.21608/acdj.2024.311877.1021

Keywords

Key Words: Post and core, PEEK, Intra-radicular impression, CAD/CAM, internal fit

Authors

First Name

Mohammad

Last Name

Al Ibrahim

MiddleName

Hasan

Affiliation

Fixed prosthodontics department, Faculty of dentistry, Cairo university, Egypt

Email

mohammad.alibrahim@dentistry.cu.edu.eg

City

-

Orcid

0009-0007-3757-1586

First Name

Ahmed

Last Name

Mohamed Farghaly

MiddleName

Farghaly

Affiliation

Fixed prosthodontics department, Faculty of Dentistry, Cairo University, Egypt

Email

dr_farghaly1952@hotmail.com

City

-

Orcid

0009-0005-6784-945X

First Name

Abdelrahman

Last Name

Badran

MiddleName

Soliman

Affiliation

Fixed prosthodontics department, Faculty of Dentistry, Cairo University, Egypt

Email

abdelrahman.badran@dentistry.cu.edu.eg

City

-

Orcid

0000-0002-0253-0289

Volume

3

Article Issue

3

Related Issue

49909

Issue Date

2024-07-01

Receive Date

2024-08-12

Publish Date

2024-07-01

Page Start

32

Page End

43

Print ISSN

2974-3087

Link

https://acdj.journals.ekb.eg/article_380664.html

Detail API

https://acdj.journals.ekb.eg/service?article_code=380664

Order

380,664

Type

Original Article

Type Code

2,514

Publication Type

Journal

Publication Title

Ahram Canadian Dental Journal

Publication Link

https://acdj.journals.ekb.eg/

MainTitle

ASSESSMENT OF INTERNAL FIT OF CUSTOM-MADE POSTS FABRICATED BY OPTICAL IMPRESSION (AN IN-VITRO STUDY)

Details

Type

Article

Created At

29 Dec 2024