Beta
330308

Retention of different types of attachments used with unilateral implant retained mandibular removable partial dentures.

Article

Last updated: 05 Jan 2025

Subjects

-

Tags

Prosthodontics and dental biomaterials

Abstract

The association between removable partial dentures (RPD) and implants is greatly valuable, especially for class I and II Kennedy classification. Proper design, with splinting of the implants and employing attachments avoids unilateral RPD compromises.
The aim of this in-vitro study was to evaluate and compare the retention of Ball attachments and OT Equator attachments used with two splinted implants retaining unilateral mandibular (RPDs).
Materials and methods: 4 identical experimental models were fabricated and categorized into two groups according to the type of attachment used (Group I) with Ball attachments and (Group II) with OT Equator attachments. Each model received two root-form implant analogs, one at the second premolar area and one at the first molar area, Theses two implants were splinted together by a metal superstructure, with attachments used to retain the unilateral RPD. Retention of the two groups was tested and compared using a Universal testing machine.
Results: In (group I), the mean retention ± standard deviation decreased from 8.07 ± 0.86 at baseline to 5.61 ± 0.74 after 450 cycles, then decreased again to 3.13 ± 0.71 after 900 cycles. In (group II), the mean retention ± standard deviation decreased from 9.89 ± 0.93 at baseline to 6.51 ± 0.90 after 450 cycles, then decreased again to 5.62 ± 0.38 after 900 cycles.
Conclusion: OT Equator showed higher retention rates than Ball with significant differences between them after 900 cycles of insertion and removal representing 6 months usage of the implant retained unilateral RPDs.

DOI

10.21608/acdj.2023.253252.1013

Keywords

Unilateral RPD, implant retained RPD, ball attachment, OT equator attachment, retention of RPD

Authors

First Name

Seham

Last Name

Mohamed

MiddleName

Esmat

Affiliation

Removable Prosthodontics department, Faculty of Dentistry, Ahram Candian University.

Email

seham.esmat@acu.edu.eg

City

-

Orcid

000000021699798X

First Name

Sahar

Last Name

Ghorab

MiddleName

-

Affiliation

Associate Professor in Removable Prosthodontic Department, Faculty of Dentistry, Ahram Canadian University.

Email

gorabsa@gmail.com

City

-

Orcid

-

Volume

2

Article Issue

4

Related Issue

44013

Issue Date

2023-10-01

Receive Date

2023-12-04

Publish Date

2023-10-01

Page Start

147

Page End

162

Print ISSN

2974-3087

Link

https://acdj.journals.ekb.eg/article_330308.html

Detail API

https://acdj.journals.ekb.eg/service?article_code=330308

Order

330,308

Type

Original Article

Type Code

2,514

Publication Type

Journal

Publication Title

Ahram Canadian Dental Journal

Publication Link

https://acdj.journals.ekb.eg/

MainTitle

Retention of different types of attachments used with unilateral implant retained mandibular removable partial dentures.

Details

Type

Article

Created At

29 Dec 2024