Beta
322993

Effect of recent severe Abutments Angulation on Implant Loaded at lower first premolar on the Fracture Resistance

Article

Last updated: 28 Dec 2024

Subjects

-

Tags

Healthcare research

Abstract

Background: The angulation of the abutment can affect the success of the dental implant because it controls the forces applied on the screw. Objectives: The goal of this research had been to assess the impact of abutment angulation on an implant loaded at the posterior mandible on the resultant stresses & and fracture resistance. Methods: To study the fracture resistance, the following method will be used. Fifteen casts representing missed lower first molar will be constructed & and divided into 3 groups (5 samples each) according to the type of abutments used: 1. The model consists of a Dental implant (4x 10 mm), internal hexagon straight abutment  and crown height of ten ml., 2. Dental implant (4x 10 mm), internal hexagon,15-degree angled abutment and a crown height of ten mm., 3. Dental implant (4x 10 mm), internal hexagon,30-degree angled abutment and a crown height of ten mm. The three groups will be subjected to fracture resistance tests. The data will be collected, tabulated and statistically analyzed. Results: 15 angled abutments showed the best fracture resistance (Fracture resistance test) in comparison to straight and 30 angled abutments. Conclusion: Angulation 15 abutment increases fracture resistance of the overlaying CAM-milled zirconia single crowns than straight abutment.

DOI

10.21608/mjmr.2023.206336.1377

Keywords

Crown height, Dental Biomechanics, Internal hexagon

Authors

First Name

Mohammed

Last Name

Hussien

MiddleName

Gamal

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, Assuit University

Email

drmohamedghh19838@gmail.com

City

-

Orcid

-

First Name

Mustafa

Last Name

Aly

MiddleName

Ahmed

Affiliation

Department of Fixed Prosthodontics, Faculty of Dentistry, EL-Ahram Canadian University, Cairo, Nahda University in Benisuief, Egypt

Email

mustafadent2014@gmail.com

City

cairo

Orcid

0000-0001-8976-6093

First Name

Cherief

Last Name

Mohsen

MiddleName

Adel

Affiliation

Department of Crown & Bridge department, Faculty of Dentistry, Minia University

Email

cherif.mohsen@gmail.com

City

-

Orcid

-

Volume

34

Article Issue

4

Related Issue

45686

Issue Date

2023-10-01

Receive Date

2023-06-15

Publish Date

2023-10-01

Page Start

162

Page End

166

Online ISSN

2682-4558

Link

https://mjmr.journals.ekb.eg/article_322993.html

Detail API

https://mjmr.journals.ekb.eg/service?article_code=322993

Order

18

Type

Original Article

Type Code

2,212

Publication Type

Journal

Publication Title

Minia Journal of Medical Research

Publication Link

https://mjmr.journals.ekb.eg/

MainTitle

Effect of recent severe Abutments Angulation on Implant Loaded at lower first premolar on the Fracture Resistance

Details

Type

Article

Created At

28 Dec 2024