Beta
299853

Bipolar Coagulation versus Ultrasonic Dissection Devices in Laparoscopic Sleeve Gastrectomy

Article

Last updated: 05 Jan 2025

Subjects

-

Tags

-

Abstract

Laparoscopic sleeve gastrectomy (LSG) comprises the first choice for treating morbid obesity in many
bariatric centers. In the era of modern laparoscopic techniques and minimally invasive surgery, tying and
knots have a limited role. New devices as ultrasonic and electrothermal bipolar have evolved in order to
achieve adequate haemostasis, tissue dissection and coagulation with reduced operating times. The aim of
this study was to compare the usage of Ligasure as one of the electrothermal bipolar devices and Harmonic
scalpel as one of the ultrasonic devices in devascularization of the greater curvature of the stomach during
LSG as regard the operative time and intra-operative and postoperative complications. There were no
statistically significant difference in the operative time and complications between both groups. The mean
operative time in Ligasure group was 100.50±15.95 minutes and in Harmonic group mean 97.71±8.21
minutes. Both Ligasure and Harmonic provide the surgeon comfort, time saving, safety and efficacy in such
a demanding operation. Choice between these two devices lies within the surgeon's preference.

DOI

10.21608/asjs.2018.299853

Keywords

sleeve gastrectomy, Bariatric surgery, Harmonic, Ligasure

Authors

First Name

Ahmed

Last Name

Sabry

MiddleName

A

Affiliation

Department of Surgery, Faculty of Medicine, Alexandria University, Egypt

Email

am.sabry1988gs5a@gmail.com

City

-

Orcid

-

First Name

Saleh

Last Name

MY

MiddleName

-

Affiliation

Department of Surgery, Faculty of Medicine, Alexandria University, Egypt

Email

-

City

-

Orcid

-

Volume

11

Article Issue

1

Related Issue

25663

Issue Date

2018-01-01

Receive Date

2023-05-21

Publish Date

2018-01-01

Page Start

49

Page End

52

Print ISSN

2090-7249

Online ISSN

3009-7509

Link

https://asjs.journals.ekb.eg/article_299853.html

Detail API

https://asjs.journals.ekb.eg/service?article_code=299853

Order

7

Publication Type

Journal

Publication Title

Ain Shams Journal of Surgery

Publication Link

https://asjs.journals.ekb.eg/

MainTitle

Bipolar Coagulation versus Ultrasonic Dissection Devices in Laparoscopic Sleeve Gastrectomy

Details

Type

Article

Created At

28 Dec 2024