Purpose
The aim was to describe a modified stop and chop technique for managing soft cataract to improve surgical safety.
Materials and methods
Capsulorrhexis is performed as usual with a 27 G needle. A trench is fashioned using low ultrasonic power. Hydrodelineation is performed by a cannula introducing directly in central lens substance. Hydrodissection follows next and precise hydroprocedure is achieved. Nucleus is emulsified using ultrasound power and intraocular lens is implanted.
Result
This technique results in easy rotation and removal of the nucleus and the epinucleus using low phaco power.
Conclusion
This modified phacoemulsification technique is safe and very effective to emulsify soft to moderate hard cataract where direct chop would be difficult.

DOI

10.4103/JCRS.JCRS_12_17

Keywords

complication, easy rotation, hydroprocedure, low phaco power, soft cataract

Authors

First Name

Mohamed M.

Last Name

Rafik

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

23

Article Issue

2

Related Issue

49502

Issue Date

2017-07-01

Receive Date

2017-01-01

Publish Date

2017-07-01

Page Start

54

Page End

56

Print ISSN

1687-6997

Online ISSN

2536-9725

Link

https://ejcrs.journals.ekb.eg/article_370239.html

Detail API

https://ejcrs.journals.ekb.eg/service?article_code=370239

Order

370,239

Publication Type

Journal

Publication Title

The Egyptian Journal of Cataract and Refractive Surgery

Publication Link

https://ejcrs.journals.ekb.eg/

MainTitle

Soft cataract: improving surgical safety with modified phacoemulsification

Details

Type

Article

Created At

28 Dec 2024