Beta
370233

Corneal parameters among normal Egyptians with Pentacam Scheimpflug camera

Article

Last updated: 28 Dec 2024

Subjects

-

Tags

-

Abstract

Purpose
The aim of the study was to evaluate the corneal parameters [anterior and posterior elevation, keratometry values in the steep () and flat () meridians, central corneal thickness, and thinnest location] among normal Egyptians of different age with Pentacam Scheimpflug camera and to detect repeatability of Pentacam.
Patients and methods
A total of 2000 randomly chosen participants representing normal Egyptian population presenting to the outpatient clinic of the Ophthalmic Center were included in the study. They were aged from 20 to 60 years and included both sexes. They were divided into four groups. All patients were examined by Pentacam Tomey TMS-5 (topographic modeling system). The technique was repeated three times for each eye on the same day and three times the next day by two different observers.
Results
There were statistically significant differences in anterior elevation, posterior elevation, central corneal thickness, thinnest location, and between the four groups (=0.02, <0.001, 0.001, 0.002, and 0.004, respectively). However, there was no statistically significant difference in between the four groups (=0.092). Coefficient of variation for and was 0.17 and 0.19, respectively.
Conclusion
There were increases in the values of posterior elevation, , and with the aging process. Excellent intraobserver and interobserver repeatability for , , and pachymetry maps and poor intraobserver and interobserver repeatability for astigmatism axis were observed.

DOI

10.4103/JCRS.JCRS_8_17

Keywords

cornea, pentacam, scheimpflug

Authors

First Name

Mona A.

Last Name

Kader

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

First Name

Ayman

Last Name

Fawzy

MiddleName

-

Affiliation

-

Email

-

City

-

Orcid

-

Volume

23

Article Issue

1

Related Issue

49501

Issue Date

2017-01-01

Receive Date

2017-05-16

Publish Date

2017-01-01

Page Start

17

Page End

22

Print ISSN

1687-6997

Online ISSN

2536-9725

Link

https://ejcrs.journals.ekb.eg/article_370233.html

Detail API

https://ejcrs.journals.ekb.eg/service?article_code=370233

Order

370,233

Publication Type

Journal

Publication Title

The Egyptian Journal of Cataract and Refractive Surgery

Publication Link

https://ejcrs.journals.ekb.eg/

MainTitle

Corneal parameters among normal Egyptians with Pentacam Scheimpflug camera

Details

Type

Article

Created At

28 Dec 2024