383657

Evaluation of Strains Induced by Two Different Implant Systems on The Supporting Structures of Implant Retained Maxillary Overdenture

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Prosthodontics

Abstract

Aim: The aim was to compare micro strains in the supporting structures around implants when using two different implant systems in implant retained maxillary overdentures by strain gauge analysis.
Materials and Methods: Digital fabrication of twelve maxillary edentulous models, each model had four implant beds at the canines and second premolars and strain gauge slots. According to the type of implant system, two groups were found; group A: Strauman, group B: JD Evolution. The universal testing machine was used to apply a 100 N load bilaterally then unilaterally. Functional simulation periods of three and six months were applied then application of same load was repeated, and data were statistically analyzed.
Results: A significant difference was found between the two groups and the lower micro strain values were in group A (Strauman). During bilateral loading, values were 39.39 and 53.52 in group A and group B respectively and during unilateral loading, values were 50.66 and 59.89 in the loaded side and 27.71 and 29.41 in the unloaded side in group A and group B respectively.
Conclusion: BLX Strauman system induced lower strain values around implants than JD Evolution system in implant retained maxillary overdenture after six months of functional simulation.

DOI

10.21608/asdj.2024.291918.1293

Keywords

Implant System, Strauman, Novaloc, Strain gauge analysis

Authors

First Name

Sawsan

Last Name

Fadl

MiddleName

Maged

Affiliation

Oral and maxillofacial department, Faculty of dentistry, Ain shams univeristy, Cairo, Egypt

Email

sawsan.maged@gmail.com

City

Cairo

Orcid

0000-0003-1414-549X

First Name

Amany

Last Name

Abdelhady

MiddleName

Ibrahim

Affiliation

Prosthodontics department, Faculty of Dentistry, Cairo univeristy, Cairo, Egypt

Email

amanyibrahim@dent.asu.edu.eg

City

Cairo

Orcid

0009-0008-2599-9646

Volume

35

Article Issue

3

Related Issue

50595

Issue Date

2024-09-01

Receive Date

2024-05-24

Publish Date

2024-09-01

Page Start

295

Page End

304

Print ISSN

1110-7642

Online ISSN

2735-5039

Link

https://asdj.journals.ekb.eg/article_383657.html

Detail API

https://asdj.journals.ekb.eg/service?article_code=383657

Order

383,657

Type

Original articles

Type Code

1,638

Publication Type

Journal

Publication Title

Ain Shams Dental Journal

Publication Link

https://asdj.journals.ekb.eg/

MainTitle

Evaluation of Strains Induced by Two Different Implant Systems on The Supporting Structures of Implant Retained Maxillary Overdenture

Details

Type

Article

Created At

28 Dec 2024