324443

Effect of CAD/CAM zirconia versus cast metal attachment on stresses induced in Kennedy class I cases ( Strain gauge analysis)

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Prosthodontics

Abstract

ABSTRACT
Background: The removable partial denture (RPD) continues to be an essential prosthetic consideration especially when edentulous ridges posterior to a patient's remaining teeth are to be restored. Precision attachments are used as extra-coronal retainers which are characterized by considerable retention improvement. In the current study, we aim to assess strains develop in supporting structures of two study groups resembling Kennedy class I partially edentulous cases which are rehabilitated with Co-Cr cast metal and CAD/CAM milled zirconia successively.
Objective: To evaluate the effect of two different extra-coronal attachments, (Co-Cr cast metal and CAD/CAM milled zirconia) on stresses induced in supporting structure in Kennedy class I cases.
Materials and Methods: This in vitro study was conducted on partially edentulous Kennedy class I cases. Two materials used in the construction of extra-coronal attachment retaining removable partial dentures were investigated; cast Co-Cr and CAD/CAM milled zirconia. The stresses induced were evaluated using the electric strain gauge analysis technique.
Results: evaluating the strains developed in both groups showed a statistically significant increase in stresses induced in the group rehabilitated with Co-Cr cast metal attachments compared to the group of CAD/CAM milled zirconia on the loaded side and a statistically insignificant difference in the unloaded side.
Conclusion: CAD/CAM milled zirconia and Co-Cr cast metal attachments showed a different distribution of forces as the zirconia attachment transmits fewer stresses to the loaded and unloaded sides compared to the metal attachment.
Keywords: Removable partial denture, Extra-coronal attachments, CAD/CAM zirconia

DOI

10.21608/asdj.2022.139651.1122

Keywords

Removable Partial Denture, extra-coronal attachments, CAD/CAM zirconia

Authors

First Name

maha

Last Name

shokr

MiddleName

abdel monsef

Affiliation

prosthodontics, faculty of dentistry, Modern university for technology and information, Cairo, Egypt

Email

maha.monsef@hotmail.com

City

cairo

Orcid

-

First Name

Injy

Last Name

Talaat

MiddleName

-

Affiliation

professor of prosthodontics, prosthodontics department, faculty of dentistry, ain shams university

Email

ingytalaat@yahoo.com

City

-

Orcid

0000-0002-1380-8944

First Name

Hebatullah

Last Name

Tarek

MiddleName

-

Affiliation

associate professor of prosthodontics, prosthodontics department, faculty of dentistry, ain shams university, Egypt

Email

hebatullah.tarek@dent.asu.edu.eg

City

-

Orcid

0000-0002-8280-4656

First Name

Ashraf

Last Name

Eskander

MiddleName

-

Affiliation

professor of prosthodontics, department of prosthodontics, faculty of dentistry, Cairo University, Cairo, Egypt

Email

ashraf.eskander@dentistry.cu.edu.eg

City

cairo

Orcid

-

Volume

30

Article Issue

2

Related Issue

44223

Issue Date

2023-06-01

Receive Date

2022-05-25

Publish Date

2023-06-01

Page Start

6

Page End

12

Print ISSN

1110-7642

Online ISSN

2735-5039

Link

https://asdj.journals.ekb.eg/article_324443.html

Detail API

https://asdj.journals.ekb.eg/service?article_code=324443

Order

4

Type

Original articles

Type Code

1,638

Publication Type

Journal

Publication Title

Ain Shams Dental Journal

Publication Link

https://asdj.journals.ekb.eg/

MainTitle

Effect of CAD/CAM zirconia versus cast metal attachment on stresses induced in Kennedy class I cases ( Strain gauge analysis)

Details

Type

Article

Created At

28 Dec 2024