Beta
321847

Assessment of prosthetic complications of customized and electrical welded frameworks in maxillary implant fixed detachable prosthesis (split mouth study)

Article

Last updated: 28 Dec 2024

Subjects

-

Tags

Prosthodontics

Abstract

This study was conducted to asses prosthetic complications, passive fit, chair side numbers and duration .cost and cost effectiveness of customized and electrical welded frameworks in maxillary implant fixed detachable prosthesis.
Methodology:
This split mouth study was performed on six completely edentulous patients received maxillary fixed detachable prosthesis, where Group I: customized framework while Group II: electric welded framework.. During prosthetic construction period for both frameworks, passive fit were done using gone screw test Assessments of prosthetic complications were evaluated 3 and 6 month later. Numbers and duration of visits .total cost and cost effectiveness were calculated
Result
Comparison between both groups revealed insignificant difference regarding all prosthetic complications. after 3 months and 6 months. The Evaluation of the passive fit revealed that in customized framework was significantly higher than electric welded group in yes, while was significantly lower in no
In group I C/E ratio (93.5) was higher than group II (85.7), as the total cost in group I was (9350), while in group II was (7150)..In number of needed visits, group I (6.83 ± 0.75) was significantly higher than group II (3.16 ±0.41) as P <0.05.
Conclusion
Maxillary fixed detachable prosthesis supported by customized or electric welded framework show no difference regarding the prosthetic complication while the electric welded framework shows highly passive fit when compared to the customized one .the cost .cost effectiveness, numbers of visits are lower and visits duration is shorter in electric welded framework when compared to the customized one

DOI

10.21608/asdj.2022.149380.1130

Keywords

welding, customized, complication

Authors

First Name

Nora

Last Name

Sheta

MiddleName

Mohamed

Affiliation

prosthodontic department faculty of dentistry Cairo university

Email

nora.sheta@dentistry.cu.edu.eg

City

cairo

Orcid

0000-0001-8152-8488

Volume

25

Article Issue

1

Related Issue

43944

Issue Date

2022-03-01

Receive Date

2022-07-06

Publish Date

2022-03-01

Page Start

35

Page End

43

Print ISSN

1110-7642

Online ISSN

2735-5039

Link

https://asdj.journals.ekb.eg/article_321847.html

Detail API

https://asdj.journals.ekb.eg/service?article_code=321847

Order

6

Type

Original articles

Type Code

1,638

Publication Type

Journal

Publication Title

Ain Shams Dental Journal

Publication Link

https://asdj.journals.ekb.eg/

MainTitle

Assessment of prosthetic complications of customized and electrical welded frameworks in maxillary implant fixed detachable prosthesis (split mouth study)

Details

Type

Article

Created At

28 Dec 2024