Beta
380131

Cooling Load Reduction in Courtyard Houses: Examining the Role of Courtyard Configuration in a Hot, Arid Climate

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Architecture Engineering and the Engineering Architectural Interior Design.

Abstract

The hot, arid climate of the Qassim region in Saudi Arabia poses significant challenges for energy-efficient building design, especially in terms of passive cooling strategies. Courtyards, a traditional architectural element, offer potential for improving thermal performance in such climates. However, the impact of courtyard plan aspect ratio and orientation on energy consumption in semi-detached houses remains understudied. This research addresses this gap by investigating the thermal behavior of U-shaped courtyards in arid climates through IES simulations. The study aims to assess the influence of different courtyard shapes (square and rectangular) and orientations (north, east, west, and south) on cooling loads in adjacent spaces. Two semi-detached house configurations, each featuring either a square or rectangular U-shaped courtyard, were modeled and analyzed. The findings indicate that square courtyards perform better than rectangular, reducing cooling loads during summer months. South-facing courtyards exhibited the highest energy consumption due to prolonged solar exposure, while west-facing courtyards had the lowest cooling loads. Furthermore, the results show that the internal zoning of rooms adjacent to the courtyard should be strategically planned based on thermal performance, as specific zones experienced varying cooling demands depending on courtyard shape and orientation. In conclusion, optimizing courtyard design, including plan aspect ratio and orientation, can significantly enhance energy efficiency and thermal comfort in arid climates. These insights provide architects with practical guidelines for designing more sustainable and energy-efficient courtyard houses. Future research could explore the integration of social and environmental aspects, as well as the impact of natural light on adjacent spaces

DOI

10.21608/jesaun.2024.299960.1346

Keywords

Courtyard, Energy efficiency, orientation, plan aspect ratio, Simulation

Authors

First Name

Essam

Last Name

Almahmoud

MiddleName

-

Affiliation

Department of Architecture, College of Architecture and Planning, Qassim University, Buraydah, 52571, Saudi Arabia.

Email

es.almahmoud@qu.edu.sa

City

Qassim, Saudi Arabia

Orcid

0000-0003-0820-6014

First Name

Lobna

Last Name

Elgheriani

MiddleName

-

Affiliation

Institut für Gebäude und Energie, Graz University of Technology, Graz, Austria

Email

lobna.arch@gmail.com

City

-

Orcid

0000-0002-9986-3628

First Name

Abdulbasit

Last Name

Almhafdy

MiddleName

-

Affiliation

Department of Architecture, College of Architecture and Planning, Qassim University, Buraydah, 52571, Saudi Arabia

Email

a.almhafdy@qu.edu.sa

City

-

Orcid

-

Volume

52

Article Issue

6

Related Issue

50144

Issue Date

2024-11-01

Receive Date

2024-06-28

Publish Date

2024-11-01

Page Start

728

Page End

738

Print ISSN

1687-0530

Online ISSN

2356-8550

Link

https://jesaun.journals.ekb.eg/article_380131.html

Detail API

https://jesaun.journals.ekb.eg/service?article_code=380131

Order

6

Type

Research Paper

Type Code

1,438

Publication Type

Journal

Publication Title

JES. Journal of Engineering Sciences

Publication Link

https://jesaun.journals.ekb.eg/

MainTitle

Cooling Load Reduction in Courtyard Houses: Examining the Role of Courtyard Configuration in a Hot, Arid Climate

Details

Type

Article

Created At

26 Dec 2024