340710

Umbilical Cord thickness, Interventricular Septum thickness and HbA1c levels in the prediction of Fetal Macrosomia in patients with Gestational Diabetes Mellitus

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

-

Abstract

Maternity care specialists are still looking for ways to properly anticipate fetal weight in order to reduce the negative consequences associated with traumatic birth. The goal of this study is to see whether assessing umbilical cord thickness, interventricular septum thickness, and HbA1c may help predict fetal macrosomia in gestational diabetes patients. This is prospective case-control research that took place between March 2020 and October 2021 on 80 pregnant women with a gestation of 36 to 37 weeks who visited Al Zahra'a Hospital, Al-Azhar University. After the local hospital ethics and research council accepted the study, the patients were separated into two groups: 40 diabetes pregnant women and 40 non-diabetic pregnant women. The diameter of the umbilical cord was  recorded using ultrasound technology. Using ultrasound machine software, the umbilical arteries and veins were measured in a free loop of the umbilical cord. The cross-sectional area of Wharton's jelly was calculated by subtracting the cross-sectional area of the vessels from that of the umbilical cord and the interventricular septum thickness was measured. The HbA1c level was determined. The mean of umbilical cord thickness of study group was (21.55 ± 4.73), umbilical vein (8.85 ± 2.16), umbilical artery (5.18 ± 1.36), Wharton's jelly (54.75 ± 15.85), IVS thickness (5.63 ± 1.55) and HbA1c (6.5 ±0.92). They had highly statistically significant difference (P=0.00) in diabetic group than control group were linked to fetal macrosomia. Using a ROC curve to assess their prediction performance for macrosomia detection, the ideal HbA1c cut-off point > 5.6 percent, with a sensitivity of 100% and a specificity of 68.25 percent (AUC 0.92; p <  0.00).Umbilical cord thickness  cut-off point > 21.5) where the sensitivity was100 % and the specificity was( 100%), (AUC 1.00; p < 0.00) and IVS thickness  cut-off point >4.9 where the sensitivity was100 % and the specificity was74.6% (AUC 0.921; p < 0.00). The Apgar score of the neonates of study group at (1,5&10) minute was significantly lower than the control group(P=0.00). There was a significant very strong positive correlation(r=0.850) between NICU duration of admission and IVS thickness (P=0.00). In individuals with gestational diabetes, ultrasound measures the diameters of the fetal umbilical cord and interventricular septum thickness, together with HbA1c levels, may help predict fetal macrosomia. Our research found a substantial very strong positive association between interventricular septum thickness and length of stay in the NICU.    

DOI

10.21608/aujv.2023.340710

Keywords

Gestational diabetes mellitus, HbA1c, Hemoglobin

Volume

5

Article Issue

4

Related Issue

46051

Issue Date

2023-12-01

Receive Date

2024-02-10

Publish Date

2023-12-01

Page Start

12

Page End

25

Print ISSN

3009-7819

Online ISSN

3009-6685

Link

https://aujv.journals.ekb.eg/article_340710.html

Detail API

https://aujv.journals.ekb.eg/service?article_code=340710

Order

340,710

Type

Original Article

Type Code

1,261

Publication Type

Journal

Publication Title

Al-Azhar University Journal of Medical and Virus Researches and Studies

Publication Link

https://aujv.journals.ekb.eg/

MainTitle

Umbilical Cord thickness, Interventricular Septum thickness and HbA1c levels in the prediction of Fetal Macrosomia in patients with Gestational Diabetes Mellitus

Details

Type

Article

Created At

25 Dec 2024