Abstract

For enhancing the human thermal comfort and lessening environmental effect, cooling of outdoor air with water misting is suggested as a way to improve performance during hot weather. This helps to create sustainable solutions. To find out the impact of various misting system characteristics, a parametric analysis study was carried out including the distance between nozzles (from 5 m to 17 m – three cases) and the number of nozzles (from 3 nozzles to 5 nozzles – three cases), along with changing the distance between nozzles along x-axis (from 0.6 m to 1.2 m – four cases). In the current study, a CFD technique was used to study 3D simulations. Discrete Phase Model (DPM) was used for calculating momentum, heat and mass exchange between the water mist and the air. The results showed that, the most successful cases at the following: (1) the distance between nozzles (∆Z = 17 m), and (2) the number of nozzles (N = 4 nozzles). Which achieves temperature and relative humidity: (1) 31.56 ℃ & 65.58%, (2) 31.53 ℃ & 65.69%, respectively. Moreover, it's observed that the best case when the distance between nozzles along x-axis (d = 0.8 m) which achieves 31.00 ℃ and 67.00% of RH.

DOI

10.21608/erj.2024.327883.1121

Keywords

Climate mitigation, Water mist, thermal comfort, Urban heat island, Evaporative cooling

Authors

First Name

Abd El-Moneim

Last Name

Harb

MiddleName

-

Affiliation

Department of Mechanical Power Engineering, Faculty of Engineering, Helwan University, Cairo, Egypt

Email

moneimharb@m-eng.helwan.edu.eg

City

-

Orcid

0000-0002-9177-9130

First Name

Ahmed

Last Name

Awwad

MiddleName

-

Affiliation

Department of Mechanical Power Engineering, Faculty of Engineering, Helwan University, Cairo, Egypt

Email

ahmedawwad@m-eng.helwan.edu.eg

City

Cairo

Orcid

-

Volume

183

Article Issue

4

Related Issue

50399

Issue Date

2024-12-01

Receive Date

2024-10-13

Publish Date

2024-12-01

Page Start

41

Page End

55

Print ISSN

1110-5615

Link

https://erj.journals.ekb.eg/article_393564.html

Detail API

https://erj.journals.ekb.eg/service?article_code=393564

Order

3

Type

Original Article

Type Code

998

Publication Type

Journal

Publication Title

Engineering Research Journal

Publication Link

https://erj.journals.ekb.eg/

MainTitle

Numerically Study for The Effect of Water Misting System on Outdoor Cooling Performance

Details

Type

Article

Created At

24 Dec 2024