Abstract

Aim :An in vitro study was conducted to compare the effects of various denture
cleansers solution on the retention of attachment systems in both conventional and digital
implant- retained overdentures. Materials and Methods: The study was conducted
according to the cleansing solution used, where divided equally into five groups: Group
A: the overdenture including retentive elements were cleaned by soaked in Corega tabs
Group B: soaked in chlorhexidine. Group C: soaked in Fittydent solution. Group D:
soaked in Sodium hypochlorite solution. Group E: soaked in EDTA cleansing solution.
Each group were placed into cleanser put in glass cup immersed in the solution during
the entire soaking period according to the manufacturers' instructions for the time
equivalent of 24 hrs., one month and six months. Acrylic blocks were held on a universal
testing machine for a pull-out test to record the dislodgement force. Measurements
were conducted after 1 months (T1) and 6 months (T2). Results: The study revealed
that, there were significant statistical differences between the different manufacturers
regarding the retention forces of the attachment's retentive force (Before soaking),
(After 24hrs), (After 1month) and (After 6 months) where (p<0.001) Except in Corega
group ,there is no statistical difference . For the cleaning solution groups, different
significant statistical results between five group at different time interval follow up.
Where (p<0.001). Conclusion: Selecting denture cleaners that necessitate minimal
soaking time is vital for both conventional and CAD/CAM-based implant-retained
overdentures with attachments, as it aids in extending the lifespan of the components.

DOI

10.21608/aadj.2024.322081.1195

Keywords

Denture cleanser, attachments, overdenture, CAD/CAM, oral health, oral hygiene, quality of life

Authors

First Name

Radwa

Last Name

Abd El-Ghany

MiddleName

Essam El-Din

Affiliation

Removable Prosthodontics Department Faculty of Dental Medicine Al-Azhar University

Email

rookaessam24@gmail.com

City

-

Orcid

-

First Name

mahmoud

Last Name

ammar

MiddleName

mohamed

Affiliation

Removable Prosthodontics, Faculty of Dentistry, Al-Azhar University, Assiut ,Egypt

Email

dr_3mmar3@yahoo.com

City

assuit

Orcid

-

First Name

Maged

Last Name

Mohamed El-Saadawy

MiddleName

Gaber

Affiliation

Removable Prosthodontics Department Faculty of Dental Medicine Al-Azhar University

Email

mageddent@hotmail.com

City

cairo

Orcid

-

Volume

7

Article Issue

2

Related Issue

51726

Issue Date

2024-10-01

Receive Date

2024-09-18

Publish Date

2024-10-01

Page Start

149

Page End

158

Print ISSN

2682-2822

Online ISSN

3009-6626

Link

https://aadj.journals.ekb.eg/article_393568.html

Detail API

https://aadj.journals.ekb.eg/service?article_code=393568

Order

393,568

Type

Review Article

Type Code

978

Publication Type

Journal

Publication Title

Al-Azhar Assiut Dental Journal

Publication Link

https://aadj.journals.ekb.eg/

MainTitle

Effect of Denture Cleansers on the Attachment System of Conventional and Digital Implant Retained Overdentures

Details

Type

Article

Created At

24 Dec 2024