296417

Clinical Comparative Study of Retention for Single Versus Two- Implant Mandibular Overdentures Reinforced by PEEK Framework

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

Prosthodontics

Abstract

Aim: This clinical work aimed to evaluate and compare retention force of single
versus 2-implants mandibular overdentures reinforced by poly ether-ether ketone
(PEEK)framework. Subjects and methods: sixteen completely edentulous participants
were eligible for this study. Patients were randomly divided into two equal groups, for
group I single implant was inserted in mandibular midline area, single ball abutment
was threaded in place, each patient receive mandibular overdenture reinforced with
PEEK framework. In group II, insertion of 2-implants in the mandibular canine
region, two ball abutments were threaded in place, each patient receives mandibular
overdenture reinforced with PEEK framework. The evaluation of retention was
performed using digital force-meter device at time of overdenture insertion (T0)
& three months later (T3). Both groups were compared with independent t- test.
Results: at time of mandibular overdenture insertion (T0), two groups were
recorded significant difference in retention forces. 2-implants with PEEK framework
recorded higher retention forces compared to single-implant with PEEK framework
(P value≤0.001). Significant difference in retention forces was recorded after 3 months
between two different groups (P value≤0.001). Within group when compared mean
retention values at (T0, T3) showed insignificant difference as in group I (P value 0.058)
& in group II (P value 0.148).Conclusion: both single and 2-implants mandibular
overdentures reinforced with PEEK framework can provide acceptable retention forces.
Two-implant mandibular overdentures provide higher retention forces than singleimplant
mandibular overdentures during different evaluation periods.

DOI

10.21608/aadj.2023.296417

Keywords

retention, PEEK framework, ball, Implant, overdenture

Authors

First Name

Heba

Last Name

Abozaed

MiddleName

Wageh

Affiliation

Prosthodontics department, Faculty of dentistry, Mansoura university, Egypt.

Email

heba_zeid@mans.edu.eg

City

Mansoura

Orcid

0000-0002-3216-7361

Volume

6

Article Issue

1

Related Issue

40964

Issue Date

2023-04-01

Receive Date

2022-10-24

Publish Date

2023-04-01

Page Start

35

Page End

44

Print ISSN

2682-2822

Online ISSN

3009-6626

Link

https://aadj.journals.ekb.eg/article_296417.html

Detail API

https://aadj.journals.ekb.eg/service?article_code=296417

Order

4

Type

Original Article

Type Code

974

Publication Type

Journal

Publication Title

Al-Azhar Assiut Dental Journal

Publication Link

https://aadj.journals.ekb.eg/

MainTitle

Clinical Comparative Study of Retention for Single Versus Two- Implant Mandibular Overdentures Reinforced by PEEK Framework

Details

Type

Article

Created At

24 Dec 2024