Beta
334447

Influence Of Different Endocrown Preparations On The Accuracy Of Multiple Intraoral Scanners-An In-Vitro Study

Article

Last updated: 04 Jan 2025

Subjects

-

Tags

-

Abstract

Objectives: This study was made to determine the accuracy of 3 intraoral scanners (IOS) on different Endocrown preparations. Methods: Four Endocrown preparations with two internal angulations (6° & 10°) and two depths (3mm & 5 mm) were made on an acrylic typodont. Reference scans were taken with a reference scanner (InEos X5) and saved in a STL format then each IOS (Trios, Omnicam, and My crown) scanned each preparation 8 times. The STL files obtained were compared to the reference scans for measuring (trueness) and within each test group (precision). A reverse engineering software was employed to measure the accuracy of the IOS. Results: Trueness: the best scanner was the Trios scanner (25.13±3.89µ) followed by My crown (37.24±6.8µ) then Omnicam (39.31±6.08µ). There was a statistically significant difference in total trueness of the Trios scanner compared to both My Crown and Omnicam. The 10° (30.87±6.74µ) was significantly higher in trueness than 6° (36.9±8.98µ). The 5mm depth (31.3±6.56µ) was significantly higher in trueness than 3mm (36.48±9.37µ). Precision: the best scanner was the Trios scanner (18.16±4.53µ) followed by Omnicam (26.21±5.24µ) then My crown (30.14±9.92µ). No significant difference in precision between 6° (24.08±8.12µ) and 10° (25.21±9.09µ). Five mm depth (20.24±5.19µ) was significantly higher in precision than 3mm (28.11±9.2µ) Conclusion: Trios scanner shows better trueness and precision than Omnicam and My crown scanners. Endocrown scans with internal angulations 10° show more accurate results than those with 6° scans, and 5mm axial wall showed more accuracy than 3mm axial wall scans.

DOI

10.21608/ajdsm.2022.130896.1329

Keywords

Intraoral scanner, Trueness, Precision, CAD/CAM, Endocrown

Authors

First Name

Ahmed

Last Name

Samir

MiddleName

-

Affiliation

Crown and bridge department , faculty of oral and dental medicine for Boys, Al-Azhar University, Cairo, Egypt

Email

ahmed084419@gmail.com

City

-

Orcid

-

First Name

Ahmad

Last Name

El-Kouedi

MiddleName

Yousri

Affiliation

Crown and Bridge, Faculty of Dental Medicine, Boys, Cairo

Email

kouedi@gmail.com

City

Cairo

Orcid

0000-0001-8726-5543

First Name

Hssein

Last Name

Mohammed

MiddleName

Ramadan

Affiliation

Department of Crown and Bridge, Faculty of Dental Medicine, Al-Azhar University in Cairo-Egypt.

Email

hussein.dent@yahoo.com

City

-

Orcid

0000-0001-7051-5913

Volume

27

Article Issue

1

Related Issue

45288

Issue Date

2024-01-01

Receive Date

2022-04-08

Publish Date

2024-01-01

Page Start

17

Page End

25

Print ISSN

1110-6751

Online ISSN

2682-3314

Link

https://ajdsm.journals.ekb.eg/article_334447.html

Detail API

https://ajdsm.journals.ekb.eg/service?article_code=334447

Order

3

Type

Review Article

Type Code

851

Publication Type

Journal

Publication Title

Al-Azhar Journal of Dental Science

Publication Link

https://ajdsm.journals.ekb.eg/

MainTitle

Influence Of Different Endocrown Preparations On The Accuracy Of Multiple Intraoral Scanners-An In-Vitro Study

Details

Type

Article

Created At

24 Dec 2024