Beta
283230

Retention and Stress Distribution of Implant Retained mandibular Complete Overdenture with Locator versus Ball and socket Attachments (An in vitro Study)

Article

Last updated: 24 Dec 2024

Subjects

-

Tags

Prosthodontics

Abstract

Abstract:
The aim of this in vitro study was to evaluate retention and stress distribution of implant retained mandibular complete overdenture with locator versus ball and socket attachments. Materials and Methods: mandibular experimental acrylic model and dentures were constructed in in the laboratory of removable prosthodontic department, faculty of dental medicine, Cairo, boys, Alazhar University. Two implants were placed in the corresponding canine areas of the models then dentures were attached to the implants by one of the studied attachment systems (Locator and Ball and socket). models with dentures were divided in to two groups according to the attachment system; (group I ) overdenture with ball/socket attachment and (group II ) overdenture with Locator attachment ; retention was evaluated using universal testing machine and stress distribution was evaluated using strain gauge. Results: The results of the present study revealed that (group II ) exhibited a statistically significant retention when compared with (group I ). While, (group II ) exhibited better but non-significant stress distribution when compared to (group I ) bilaterally and unilaterally. Conclusion: Locator attachment system could provide better retention and stress distribution for implant retained mandibular complete overdenture.

DOI

10.21608/ajdsm.2021.63954.1169

Keywords

ball and socket, locator, overdenture, retention, Stress distribution

Authors

First Name

هشام

Last Name

القرياتي

MiddleName

عبد النعيم

Affiliation

Department of Removable Prosthodontic Faculty Of Dental Medicine Boys, Cairo, Al-Azhar University.

Email

heshamelqouriaty@gmail.com

City

سوهاج

Orcid

-

First Name

محمد

Last Name

قاسم

MiddleName

عبدالله

Affiliation

Department of Removable Prosthodontic Faculty Of Dental Medicine Boys, Cairo, Al-Azhar University.

Email

basma.hesham.yassen@gmail.com

City

القاهرة

Orcid

-

First Name

osama

Last Name

helaly

MiddleName

abdel hamid

Affiliation

Lecturer, Department of Removable Prosthodontic Faculty Of Dental Medicine, Boys, Cairo Al-Azhar University

Email

who.camm.call@gmail.com

City

cairo

Orcid

-

Volume

26

Article Issue

1

Related Issue

39201

Issue Date

2023-01-01

Receive Date

2021-02-21

Publish Date

2023-01-01

Page Start

1

Page End

7

Print ISSN

1110-6751

Online ISSN

2682-3314

Link

https://ajdsm.journals.ekb.eg/article_283230.html

Detail API

https://ajdsm.journals.ekb.eg/service?article_code=283230

Order

1

Type

Original Article

Type Code

848

Publication Type

Journal

Publication Title

Al-Azhar Journal of Dental Science

Publication Link

https://ajdsm.journals.ekb.eg/

MainTitle

Retention and Stress Distribution of Implant Retained mandibular Complete Overdenture with Locator versus Ball and socket Attachments (An in vitro Study)

Details

Type

Article

Created At

24 Dec 2024