Beta
343816

Effect of Using Two Different Techniques of Denture Base Fabrication on Retention of Maxillary Complete Denture: An in Vivo Comparative Study

Article

Last updated: 24 Dec 2024

Subjects

-

Tags

Fixed and removable prosthodontics

Abstract

Introduction: Complete denture is used to replace the entire dentition and restore
mastication, speech, and aesthetics. All other tooth-supported solutions have been
exhausted. Because Computer-Aided Design/ Computer-Aided Manufacturing (CAD/
CAM) dentures are milled from pre-polymerized Polymethyl Methacrylate (PMMA)
blocks that do not display polymerization shrinkage, they can eliminate the laboratory
processes of acrylic processing (setting up of teeth, try-in, flasking and de flasking).
Aim: to compare the retention values of maxillary conventional heat-polymerized
denture bases with digitally milled denture bases. Materials and Methods: Sixteen
totally edentulous patients participated in the study, which was divided into two groups
(n=8) (A) and (B). Patients in the group (A) received traditional heat-cured acrylic resin
dentures with a long cycle water path curing procedure, in group (B) received dentures
created using the CAD/CAM technique. For both groups, a metallic hook affixed to the
geometric center of the maxillary dentures was pulled by a digital force-meter gauge to
measure retention. Results: The mean retention values were recorded for both groups,
tabulated, and statistically analyzed; the following results were obtained. Regarding
group (A), retention values showed a significant increase at the beginning of the
study as well as at the end of the study. Regarding group (B), retention values showed
a significant initial increase at the beginning of the study, till the end of the study.
A significant difference was revealed between the mean retention values of the two
tested groups, with clear superiority of the retention of the CAD/CAM acrylic resin
dentures (group B) than that of the conventional heat-cured acrylic resin dentures
(group A). Conclusion: CAD/CAM acrylic resin dentures were superior in terms of
maxillary denture retention compared to conventional heat-cured acrylic resin dentures.
Retention was increased gradually over time in both two studied groups.

DOI

10.21608/dsu.2024.182953.1152

Keywords

CAD/CAM denture base, Digitally Milled, maxillary, Conventional Heat-Polymerized

Authors

First Name

Ayah

Last Name

Abdellatif

MiddleName

Ahmed

Affiliation

Faculty of dentistry Suez Canal University

Email

dentayah1988@gmail.com

City

Suez

Orcid

-

First Name

Moataz

Last Name

Bahgat

MiddleName

Mostafa

Affiliation

Professor of prosthodontics, Faculty of Dentistry, Suez Canal University.Egypt.

Email

moatazmm12343@yahoo.com

City

Suez Canal

Orcid

0000-0000-5990-4329

First Name

Sayed

Last Name

Elmasry

MiddleName

-

Affiliation

Professor of Prosthodontics, Faculty of Dentistry – Suez Canal University.

Email

sydelmsry@yahoo.com

City

-

Orcid

0009-0003-8879-3745

First Name

Khaled

Last Name

Sultan

MiddleName

Omran

Affiliation

Assistant Professor of Prosthodontics, Faculty of Dentistry – Suez Canal University.

Email

kh.omran@yahoo.com

City

-

Orcid

-

Volume

5

Article Issue

1

Related Issue

45584

Issue Date

2024-03-01

Receive Date

2022-12-28

Publish Date

2024-03-01

Page Start

39

Page End

48

Print ISSN

2636-3836

Online ISSN

2636-3844

Link

https://dsu.journals.ekb.eg/article_343816.html

Detail API

https://dsu.journals.ekb.eg/service?article_code=343816

Order

3

Type

Original Article

Type Code

772

Publication Type

Journal

Publication Title

Dental Science Updates

Publication Link

https://dsu.journals.ekb.eg/

MainTitle

Effect of Using Two Different Techniques of Denture Base Fabrication on Retention of Maxillary Complete Denture: An in Vivo Comparative Study

Details

Type

Article

Created At

24 Dec 2024