Beta
386175

Effect of Inter-implant Distance on the Accuracy of Intraoral Scanner Following All on-4 Concept: An In-vitro Study

Article

Last updated: 24 Dec 2024

Subjects

-

Tags

Prosthodontics

Abstract

Aim: This study aimed to assess the accuracy of intraoral scanner (IOS) Medit i700 in scanning All-on-4 implant rehabilitation. Subjects and methods: An edentulous mandibular model was designed with two straight anterior and two angulated posterior implants. The two test groups; were a short interimplant distance group (S) where the master model was fitted with two anterior and two posterior implants at the first premolar region. The second was the long interimplant distance group (L) two anterior and two posterior implants at the second premolar region. The model was scanned once with the extraoral scanner inEos X5, to obtain the reference scan and 10 times with the IOS, to obtain the test scans. Results: Following statistical analysis it was evident that interimplant distance increase had no statistically significant influence on the accuracy of digital data obtained by Medit i700 wired. Conclusion: Interimplant distance had no statistically significant effect on the accuracy.

DOI

10.21608/adjc.2024.257643.1450

Keywords

Optical imaging / instrumentation, models, Dental implants, Edentulous / rehabilitation

Authors

First Name

Nour El Hoda

Last Name

EL Tarabishi

MiddleName

Mahmoud

Affiliation

Prosthodontic Department, Faculty of dentistry, Cairo University, Cairo, Egypt.

Email

nourelhodaeltarabishi@dentistry.cu.edu.eg

City

-

Orcid

https://orcid.org/00

First Name

Nesma

Last Name

Awaad

MiddleName

Mohamed

Affiliation

Prosthodontic Department, Faculty of dentistry, Cairo University, Cairo, Egypt.

Email

nesmaawaad@dentistry.cu.edu.eg

City

Cairo

Orcid

0000-0001-6720-4567

First Name

Amr

Last Name

Elkhadem

MiddleName

-

Affiliation

Prosthodontic Department, Faculty of dentistry, Cairo University, Cairo, Egypt.

Email

amrelkhadem@gmail.com

City

-

Orcid

-

First Name

Khaled

Last Name

Zekry

MiddleName

Ahmed

Affiliation

Prosthodontic Department, Faculty of dentistry, Cairo University, Cairo, Egypt.

Email

kzekry@hotmail.com

City

-

Orcid

-

Volume

6

Article Issue

4

Related Issue

50701

Issue Date

2024-10-01

Receive Date

2024-01-27

Publish Date

2024-10-01

Page Start

691

Page End

696

Print ISSN

2636-302X

Online ISSN

2636-3038

Link

https://adjc.journals.ekb.eg/article_386175.html

Detail API

https://adjc.journals.ekb.eg/service?article_code=386175

Order

386,175

Type

Original Article

Type Code

688

Publication Type

Journal

Publication Title

Advanced Dental Journal

Publication Link

https://adjc.journals.ekb.eg/

MainTitle

Effect of Inter-implant Distance on the Accuracy of Intraoral Scanner Following All on-4 Concept: An In-vitro Study

Details

Type

Article

Created At

24 Dec 2024