Beta
350930

ASSESSEMENT OF TRUENESS AND PRECISION OF FDM 3D PRINTED MAXILLARY ARCH MODELS OBTAINED FROM CBCT SCANS

Article

Last updated: 24 Dec 2024

Subjects

-

Tags

Radiology

Abstract

Purpose: The aim of this study was to assess the trueness and precision of three dimensional (3D) printed maxillary arch models obtained by fused deposition modelling (FDM) based on CBCT scan data.
Materials and Methods: A human skull was scanned by cone beam computed tomography (CBCT) to obtain the Standard Tessellation Language (STL) file of maxillary bone, then three maxillary models were printed by FDM technique. For dimensional accuracy assessment, nine linear measurements were selected and measured using digital caliper on both the skull and the printed models. The recorded measurements were compared to their corresponding measurements on skull (trueness assessment), and the measurements in each one of the 3 models were compared together (precision assessment), then data were statistically analysed.
Results: In trueness assessment, FDM printed models shows no statistically significant differences in overall dimensions, the recorded mean absolute difference was 0.05 mm, and the mean relative difference was 0.15%. However, regarding the precision, the results revealed a significant difference in the overall dimensional error in the 3 models compared to each other.
Conclusions: FDM constructed maxillary models had minimal dimensional error, which was statistically and clinically insignificant, hence they can be used safely in the dental clinical with comparable accuracy to the models produced by more expensive 3D printing techniques.

DOI

10.21608/adjc.2023.231957.1389

Keywords

CBCT, 3D printing, FDM, Maxillary models

Authors

First Name

Arwa

Last Name

Mousa

MiddleName

-

Affiliation

Oral and Maxillofacial Radiology, Faculty of Dentistry, Cairo University, Cairo, Egypt

Email

arwa.mousa@dentistry.cu.edu.eg

City

-

Orcid

0000-0001-8606-8353

First Name

Noran

Last Name

Hesham

MiddleName

-

Affiliation

Oral Maxillofacial Radiology, Faculty of Oral and Dental Medicine, Ahram Canadian University

Email

noran.hesham@acu.edu.eg

City

-

Orcid

0009-0000-3170-8122

Volume

6

Article Issue

2

Related Issue

46986

Issue Date

2024-04-01

Receive Date

2023-08-26

Publish Date

2024-04-01

Page Start

406

Page End

416

Print ISSN

2636-302X

Online ISSN

2636-3038

Link

https://adjc.journals.ekb.eg/article_350930.html

Detail API

https://adjc.journals.ekb.eg/service?article_code=350930

Order

350,930

Type

Original Article

Type Code

688

Publication Type

Journal

Publication Title

Advanced Dental Journal

Publication Link

https://adjc.journals.ekb.eg/

MainTitle

ASSESSEMENT OF TRUENESS AND PRECISION OF FDM 3D PRINTED MAXILLARY ARCH MODELS OBTAINED FROM CBCT SCANS

Details

Type

Article

Created At

24 Dec 2024